Prosthodontics MCQs for Dental NMCLE / Loksewa / MDS Exams – Page 8
150 Prosthodontics multiple-choice questions with answers and explanations, from the ExamsNepal question bank for Dental NMCLE / Loksewa / MDS Exams. Try each question first, then open the answer to check your reasoning.
In ExamsNepal mock tests, students answer 54% of Prosthodontics questions correctly (935 answers).
Preparing for MDS Entrance Exam (Master of Dental Surgery)? See the exam pattern, syllabus and free mock tests.
141. A complete denture patient complains of the teeth clicking while speaking. What is the most likely cause?
- A. Inadequate vertical dimension of occlusion
- B. Overextended lingual flange
- C. Incorrect centric relation record
- D. Excessive vertical dimension of occlusion
Discuss this questionShow answer & explanation
Answer: D. Excessive vertical dimension of occlusion
Clicking of teeth during speech is a classic sign of an excessive vertical dimension of occlusion, which reduces or eliminates the interocclusal rest space (freeway space, normally 2 to 4 mm). The teeth come into contact while the patient pronounces sibilant sounds, causing clicking. Other signs include strained appearance of the lips, fatigue of masticatory muscles, soreness of the ridges and rapid ridge resorption. An inadequate vertical dimension instead produces collapsed facial appearance, angular cheilitis, prominent chin and decreased masticatory efficiency. The closest speaking space (Silverman), about 1 mm in 's' sounds, is a practical test. Treatment involves resetting teeth at a correct vertical dimension.142. A complete denture patient bites the cheek in the molar region. Which correction is most appropriate?
- A. Reduce the lingual cusps of mandibular molars
- B. Increase the vertical dimension of occlusion
- C. Reduce the buccal surface of the mandibular buccal cusps to increase horizontal overlap
- D. Reduce the lingual surface of maxillary lingual cusps
Discuss this questionShow answer & explanation
Answer: C. Reduce the buccal surface of the mandibular buccal cusps to increase horizontal overlap
Cheek biting in the posterior region usually occurs when posterior teeth are set with an edge-to-edge or insufficient horizontal overlap, so the buccal mucosa is trapped between the buccal cusps. Correction is to create adequate horizontal overlap (overjet) by reducing the buccal surface of the mandibular buccal cusps, which moves the mandibular tooth contour lingually relative to the maxillary teeth. This differs from occlusal adjustment under the BULL rule, which is used for centric and working-side interferences. Tongue biting is managed by reducing the lingual surface of maxillary lingual cusps. Setting mandibular teeth too far buccally from the neutral zone, or an inadequate posterior vertical dimension, can also contribute.143. According to Misch, which bone density is typically found in the posterior maxilla?
- A. D1
- B. D2
- C. D3
- D. D4
Discuss this questionShow answer & explanation
Answer: D. D4
Misch classified bone density into four types. D1 is dense cortical bone, found mainly in the anterior mandible. D2 is thick, dense to porous cortical bone with coarse trabeculae, typical of the anterior and posterior mandible. D3 is thin porous cortical crest with fine trabecular bone, found in the anterior maxilla and sometimes the posterior mandible. D4 is fine trabecular bone with little or no cortical crest and is characteristic of the posterior maxilla, especially after tooth loss. D4 bone gives the lowest primary stability and the highest implant failure rate, so it needs longer healing, wider or tapered threaded implants, osteotome or undersized preparation, and progressive loading.144. What is the minimum inter-implant distance recommended (Tarnow) to preserve the crestal bone between two adjacent implants?
- A. 1 mm
- B. 1.5 mm
- C. 2 mm
- D. 3 mm
Discuss this questionShow answer & explanation
Answer: D. 3 mm
Tarnow and colleagues showed that when two implants are placed less than 3 mm apart, there is increased crestal bone loss between them, leading to loss of the interimplant papilla. Each implant develops about 1.3 to 1.4 mm of lateral bone remodelling around the platform after the biologic width forms. If the implants are closer than 3 mm, these zones overlap and the interproximal bone height falls. Between an implant and a natural tooth, at least 1.5 mm is recommended. Tarnow also showed that a papilla fills the embrasure nearly 100% of the time when the distance from contact point to bone crest is 5 mm or less between teeth, and that implant to implant papillae are typically shorter, about 3.4 mm.145. What is the main mechanism by which platform switching reduces crestal bone loss around implants?
- A. It increases implant surface area for osseointegration
- B. It moves the implant-abutment microgap and its inflammatory infiltrate inward, away from the crestal bone
- C. It eliminates micromotion between implant and bone completely
- D. It increases the thickness of keratinised mucosa
Discuss this questionShow answer & explanation
Answer: B. It moves the implant-abutment microgap and its inflammatory infiltrate inward, away from the crestal bone
Platform switching uses an abutment of smaller diameter than the implant platform, shifting the implant-abutment junction (microgap) horizontally inward. Bacterial colonisation of the microgap creates an inflammatory cell infiltrate, which normally leads to bone resorption of about 1.5 to 2 mm around a conventionally matched implant to establish biologic width. Moving the junction inward places this infiltrate further from the bone and allows part of the biologic width to form horizontally, preserving crestal bone. It also reduces stress concentration at the crestal bone. The concept was discovered accidentally by Lazzara and Porter when wider implants were restored with standard abutments. It does not affect implant surface area.146. Which Aramany class of maxillectomy defect is the most common?
- A. Class I
- B. Class II
- C. Class III
- D. Class IV
Discuss this questionShow answer & explanation
Answer: A. Class I
Aramany classified partially edentulous maxillectomy defects into six classes. Class I is a midline resection removing one half of the maxilla, with teeth remaining on the opposite side; it is the most common defect. A tripodal design with a straight line arrangement of retainers is recommended. Class II is a unilateral defect with the anterior teeth on the opposite side remaining, the second most common, also treated with a tripodal design. Class III is a central palatal defect with all teeth retained. Class IV crosses the midline involving both sides. Class V is posterior, with anterior abutments, and Class VI is anterior, with posterior teeth remaining. Classes IV and V have the poorest retention.147. Which prosthesis is used to correct mandibular deviation after segmental mandibulectomy without bony reconstruction?
- A. Palatal lift prosthesis
- B. Speech bulb obturator
- C. Guide flange prosthesis
- D. Palatal augmentation prosthesis
Discuss this questionShow answer & explanation
Answer: C. Guide flange prosthesis
After segmental mandibulectomy without reconstruction, the residual mandible deviates toward the defect side due to unopposed pull of the remaining muscles and scar contracture, causing malocclusion and poor masticatory function. A guide flange prosthesis is a removable mandibular appliance with a flange extending buccally that contacts the maxillary teeth and guides the mandible into the correct intercuspal position, helping the patient learn proper closure. Exercises and a palatal-based guidance ramp are also used. A palatal augmentation prosthesis lowers the palate for tongue contact after glossectomy. Palatal lift and speech bulb prostheses manage velopharyngeal incompetence and insufficiency, not mandibular deviation.148. A patient has a soft palate of adequate length but poor movement due to a neuromuscular disorder. Which prosthesis is indicated?
- A. Palatal lift prosthesis
- B. Speech bulb obturator
- C. Interim obturator
- D. Guide flange prosthesis
Discuss this questionShow answer & explanation
Answer: A. Palatal lift prosthesis
Velopharyngeal dysfunction is divided into insufficiency (lack of tissue, such as a short or surgically resected palate) and incompetence (adequate tissue with poor function, for example due to stroke, cerebral palsy, myasthenia gravis or other neurological disorders). In incompetence, the soft palate has sufficient length but cannot elevate to close the velopharyngeal port, so a palatal lift prosthesis is used to raise the palate passively toward the posterior pharyngeal wall. The tissue must be flexible and not too spastic. In insufficiency, a speech bulb (pharyngeal) obturator is used to fill the defect between the palate and the pharyngeal wall. Combination prostheses are sometimes needed in mixed cases.149. A mandibular second molar abutment is mesially tilted, and orthodontic uprighting is not possible. Which retainer is preferred on this tooth?
- A. Three-quarter crown
- B. Proximal half crown
- C. Full veneer crown with conventional preparation
- D. Inlay
Discuss this questionShow answer & explanation
Answer: B. Proximal half crown
When a mandibular second molar drifts mesially into the space of a lost first molar, its long axis becomes nonparallel with the premolar abutment. Orthodontic uprighting is the first choice. If that is not possible, Shillingburg recommends a proximal half crown, essentially a three-quarter crown rotated 90 degrees so that the distal surface is left uncovered. This allows a common path of insertion with the premolar retainer without excessive tooth reduction, provided the distal surface is caries-free and oral hygiene is good. Alternatively a telescope crown with coping or a nonrigid connector can be used. A conventional full crown on a tilted molar would need excessive reduction of the mesial wall and risk pulp exposure.150. A maxillary complete denture dislodges when the patient opens wide or moves the mandible laterally. What is the most likely cause?
- A. Thick distobuccal flange interfering with the coronoid process
- B. Overextended labial flange
- C. Underextended posterior palatal seal
- D. Inadequate relief of the incisive papilla
Discuss this questionShow answer & explanation
Answer: A. Thick distobuccal flange interfering with the coronoid process
The distobuccal area of the maxillary denture lies in the space between the residual ridge and the coronoid process of the mandible. When the patient opens wide or moves the mandible to the same side, the coronoid process moves forward and medially. If the distobuccal flange is too thick in this region, it contacts the coronoid process, which displaces the denture. Correction is to thin the distobuccal flange, which is why the patient is asked to open wide and move the mandible side to side during border moulding. An overextended labial flange causes dislodgement during smiling or lip movement, while an underextended posterior palatal seal causes loss of retention and gagging, not displacement linked to jaw opening.