A maxillary complete denture dislodges when the patient opens wide or moves the mandible laterally. What is the most likely cause?

55 views
  • Thick distobuccal flange interfering with the coronoid process (Correct Answer)
  • Overextended labial flange
  • Underextended posterior palatal seal
  • Inadequate relief of the incisive papilla

Explanation

The distobuccal area of the maxillary denture lies in the space between the residual ridge and the coronoid process of the mandible. When the patient opens wide or moves the mandible to the same side, the coronoid process moves forward and medially. If the distobuccal flange is too thick in this region, it contacts the coronoid process, which displaces the denture. Correction is to thin the distobuccal flange, which is why the patient is asked to open wide and move the mandible side to side during border moulding. An overextended labial flange causes dislodgement during smiling or lip movement, while an underextended posterior palatal seal causes loss of retention and gagging, not displacement linked to jaw opening.

Comments (0)

No comments yet. Be the first to comment!

Want to practice more?

Explore thousands of MCQs across every exam category on Exams Nepal.

Find More MCQs