You are evaluating a new composite resin claimed to have low polymerization shrinkage due to silorane-based chemistry. Which test would best confirm a lower shrinkage stress compared to conventional methacrylate composite?
12 views
- Measure color stability after thermal cycling
- Perform Knoop hardness depth-of-cure test only
- Evaluate fluoride release
- Measure volumetric shrinkage via dilatometry and concurrently measure shrinkage stress using a bonded-disk tensometer under constrained conditions (Correct Answer)
Explanation
To confirm low shrinkage and low shrinkage stress, direct measurement of volumetric shrinkage (dilatometry) and mechanical stress development under constrained bonding conditions (tensometer or strain-gauge) are required. Hardness, color, and fluoride release do not directly measure shrinkage stress.