Which of the following isotopes is used for RAIU ?

25 views
  • I 123 (Correct Answer)
  • I 125
  • I 131
  • I 132

Explanation

Answer: A. I 123

I123 is used as an isotope for RAI U.
RAIU: Radioactive iodine uptake/ Thyroid count /capsule count is a thyroid imaging method that measures the fraction of orally administered iodine isotope taken up by the thyroid. It is measured at intervals of 4 & 24 hours,after administration of the isotope.
The various modalities of thyroid scintigraphy are:
• Tc 99 m pertechnitate scan
• I123 scan_[Agent of choice]
• I121
Interpretation of RAIU
Increased
In Graves disease
Normal
< 25% at 4 hours
< 35% at 24 hrs
Decreased
Insubacute thyroiditis
*However RAIU is not diagnostic of hyperthyroidism without measurement of hormonal levels.