Which of the following condition should be satisfied for spacing of lacings?
31 views
- maximum slenderness ratio of component of main members between two consecutive lacing connection should not be more than 0.9 x most unfavourable slenderness ratio of combined column
- maximum slenderness ratio of component of main members between two consecutive lacing connection should be not greater than 50 (Correct Answer)
- maximum slenderness ratio of component of main members between two consecutive lacing connection should be more than 0.7 x most unfavourable slenderness ratio of combined column
- maximum slenderness ratio of component of main members between two consecutive lacing connection should be greater than 50
Explanation
The spacing of lacing bars should be such that the maximum slenderness ratio of components of main members between two consecutive lacing connections is not greater than 50. It should not be greater than 0.7 times the most unfavorable slenderness ratio of combined column.