Which o the following is correct regarding operating room fires?
- Two of the three components of the classically described “ fire triad” must be present for an OR fire to occur.
- The most common OR fire fuel is the monopolar electrosurgical cautery “Bovie”.
- An oxidizer enriched atmosphere often exists in the entire operating room.
- Alcohol containing prep solutions need to be completely dry before starting a procedure. (Correct Answer)
Explanation
Correct Answer: D.
In order for a fire to occur, all three components of the “fire triad” must be present. These include Fuel, and oxidizer, and an ignition source. Fuel for fire is plentiful in the operating room. Some examples include drapes, patient’s hair, surgical gowns, blankets, endotracheal tubes, and lyngeal mask airways
and volatile surgical compounds (e.g., alcohol containing prep solutions, acetone, etc.). It has been
shown that alcohol containing prep solutions with as little as 20% alcohol can ignite with diathermy or hot wire cautery and so they must be allowed to dry before surgical electricity is used. Oxidizers in
the operating room are generally either oxygen or nitrous oxide. These oxidizers can accumulate and
form an oxidizer enriched atmosphere in closed or semi-closed breathing systems and from tenting of
surgical drapes. Ignition sources in the operating room are equally as plentiful. Some common examples include electrosurgical devices, heated probes, lasers, fiberoptic light cables, argon beam coagulators, drills and de brillator pads.