Which MRI sequence is most sensitive for detecting acute ischemic stroke?
15 views
- T1-weighted
- T2-weighted
- FLAIR
- Diffusion-weighted imaging (DWI) (Correct Answer)
Explanation
DWI is highly sensitive for acute ischemic changes within minutes, showing restricted diffusion. T1 is poor for acute stroke, T2 may show hyperintensity later, and FLAIR helps detect subacute strokes but is less sensitive initially. Early DWI detection improves thrombolytic therapy outcomes.