Which indicator is MOST suitable for titration of a weak acid with a strong base?
13 views
- Methyl orange
- Phenolphthalein (Correct Answer)
- Litmus
- Bromothymol blue
Explanation
In weak acid–strong base titration, the equivalence point lies in the alkaline range (pH > 7). Phenolphthalein changes color around pH 8.2–10, making it ideal. Methyl orange changes in acidic range and is unsuitable.