When a diagnostic test is used in “series” mode, then:
- Sensitivity increases but specificity decreases
- Specificity increases but sensitivity decreases (Correct Answer)
- Both sensitivity and specificity increase
- Both sensitivity and specificity decrease
Explanation
Correct Answer :- B. Specificity increases but sensitivity decreases
[Ref. Simple Biostatistics by Indrayan & Indrayan, 1/e p56; Park 23/e p139]
SCREENING TESTS USED IN SERIES:
A population is subjected to one screening test followed by a second screening test; 2nd screening test is applied on those individuals only who test positive on the 1st screening test
• Combined sensitivity of 2 tests A & B in series: Sensitivity (A) × Sensitivity (B)
• Combined specificity of 2 tests A & B in series: [(Specificity A) + (Specificity B)] – [(Specificity A) × (Specificity B)]
SCREENING TESTS USED IN PARALLEL:
A population is subjected to two (or more) screening tests at the same time; each of the individuals is subjected to both (or all) screening tests
• Combined sensitivity of 2 tests A & B in parallel: [(Specificity A) + (Specificity B)] – [(Specificity A) × (Specificity B)]
• Combined specificity of 2 tests A & B in parallel: Specificity (A) × Specificity (B)
Combined sensitivity
Combined specificity
Combined PPV
Combined NPV
Tests in series
Decreases
Increases
Increases
Decreases
Tests in parallel
Increases
Decreases
Decreases
Increases