What is the SI unit of equivalent dose and effective dose used for radiation protection purposes?
- Becquerel
- Sievert (Correct Answer)
- Roentgen
- Gray
Explanation
Radiation quantities and units are a frequently tested area. ABSORBED DOSE is the energy deposited per unit mass of tissue, measured in GRAY (Gy), where 1 Gy = 1 joule/kg (the old unit was the rad; 1 Gy = 100 rad). Radiotherapy doses are prescribed in Gy, for example 60 Gy in 30 fractions. EQUIVALENT DOSE = absorbed dose x radiation weighting factor (WR: 1 for X-rays, gamma rays and electrons; 20 for alpha particles; energy-dependent for neutrons). It reflects the biological effectiveness of different radiation types and is measured in SIEVERT (Sv) (old unit: rem; 1 Sv = 100 rem). EFFECTIVE DOSE = sum of equivalent doses x tissue weighting factors (WT; for example the bone marrow, colon, lung, stomach and breast are highly weighted). It estimates the overall stochastic (cancer) risk from non-uniform exposure and is also in Sv, making it the main quantity for radiation protection and for comparing imaging procedures. BECQUEREL (Bq) measures radioactivity: one disintegration per second (old unit: curie; 1 Ci = 3.7 x 10^10 Bq). The ROENTGEN is an old unit of EXPOSURE (ionisation in air). Typical effective doses: chest X-ray about 0.02 mSv, CT head about 2 mSv, CT abdomen-pelvis about 8-10 mSv, annual natural background about 2.4 mSv. ICRP dose limits: occupational 20 mSv/year averaged over 5 years (maximum 50 in any single year); general public 1 mSv/year. Protection principles: justification, optimisation (ALARA) and dose limitation, with time, distance (inverse square law) and shielding.