What is the primary function of a surge tank in a hydropower scheme?

5 views
  • To trap bed load before it enters the headrace
  • To reduce water-hammer pressures and absorb flow changes during load variation (Correct Answer)
  • To increase the net head on the turbine
  • To supply cooling water to the generator

Explanation

A surge tank provides a free water surface between the headrace tunnel and the penstock. It absorbs pressure surges from sudden load rejection and supplies water during sudden load acceptance, protecting the low-pressure conduit from water hammer.