What are the standard conditions for moist-heat sterilization of unwrapped instruments in an autoclave?

14 views
  • 100°C at atmospheric pressure for 20 minutes
  • 160°C dry heat for 2 hours
  • 121°C at a pressure of 15 lb/in² (about 106 kPa) for at least 20 minutes (Correct Answer)
  • 70°C for 30 minutes

Explanation

Autoclaving uses saturated steam under pressure. At 15 lb/in² above atmospheric pressure, water boils at 121°C, and moist heat at this temperature coagulates proteins of all microorganisms, including bacterial spores, which are the most resistant forms. Unwrapped instruments are sterilized for at least 20 minutes and wrapped packs for about 30 minutes; the timing starts only after the correct temperature and pressure are reached. Moist heat is more effective than dry heat at the same temperature because steam penetrates better and transfers heat by condensation. Boiling at 100°C for 20 minutes is high-level disinfection; it kills vegetative bacteria and most viruses but does not reliably destroy spores, so it is not sterilization. A temperature of 160°C for 2 hours is the hot air oven (dry heat) method, used for glassware, oils and powders, not autoclaving. Heating at about 70°C is in the range of pasteurization, which only reduces the number of pathogens in milk.

Comments (0)

No comments yet. Be the first to comment!