True about pure tone audiometry:

28 views
  • The frequency tested is 2000-9000Hz
  • Done in silent room (Correct Answer)
  • Air conduction for right ear is represented on audiogram by symbol "X"
  • Air conduction for left ear is represented on audiogram by symbol "O"

Explanation

Correct Answer:- "B" Done in silent room

Ref. P.L.Dhingra 6/e,pgs23; Logan Turner 10/e,pgs248-49; Textbook of ENT by Maqbool 11/e,pgs134-36

Pure Tone Audiometry
Usually air conduction thresholds are measured for tones of 125, 250, 1000, 2000, 4000 & 8000 Hz& bone conduction thresholds
for 250, 500, 1000, 2000, 4000Hz (i.e. option a is correct)
In a soundproof room, the patients ability to hear pure tones in the frequency range of about 125 to 8000 Hz is measured
Symbols on audiogram: Red "0" represents air conduction for the right ear while blue "X" represents air conduction for the left
ear. The symbol of > is for bone conduction of the right ear & symbol < for bone conduction of the left ear.

Comments (0)