To move a maxillary incisor bodily (translation) with a force applied at the bracket, the clinician must apply a moment-to-force (M/F) ratio of approximately:
- 1:1 (mm), since a small moment is enough for translation
- 0:1, meaning a pure force at the bracket with no moment
- 20:1 (mm), since a large moment is needed
- 8-10:1 (mm) (Correct Answer)
Explanation
Orthodontic brackets are on the crown, at a distance from the tooth's centre of resistance. For a single-rooted tooth, the centre of resistance lies about one-third to two-fifths of the root length apical to the alveolar crest. A force applied at the bracket therefore creates a moment (force multiplied by the perpendicular distance), which tips the tooth around a centre of rotation close to the centre of resistance. To control the type of movement, a counter-moment is added (through the wire in the bracket slot, for example torque or tip bends), and the ratio of the applied couple to the force (M/F) determines where the centre of rotation lies. A ratio of about 0-5:1 gives uncontrolled tipping (centre of rotation near the centre of resistance). About 7:1 gives controlled tipping (centre of rotation at the apex). About 8-10:1 gives translation (the centre of rotation moves to infinity). Above about 10-12:1, root movement or torque occurs (centre of rotation at the incisal edge). These values depend on root length and bone level; in patients with periodontal bone loss the centre of resistance moves apically, so a larger M/F ratio is needed.