The Sengstaken tube must maintain a pressure of... to stop bleeding from varices:
- 20 mm Hg
- 25 mm Hg
- 35 mm Hg (Correct Answer)
- 45 mm Hg
Explanation
Correct Answer :- C. 35 mm Hg
(Ref: Sabiston 19/e p1433; Schwartz 9/e p1113; Blumgart 5/e p1136-1137; Shackelford 7/e p1600; Harrison 18/e p2598; Bailey 25/e p1089)
• If bleeding does not stop promptly, the gastric balloon may be inflated to at least a volume of 300 mL, or the esophageal balloon may be inflated to a pressure of 40 mm Hg.
Balloon Tamponade
• Sengstaken and Blakemore designed a triple-lumen (esophageal balloon, gastric balloon, and gastric aspiration) tube.
Modifications
• Addition of a fourth port above the esophageal balloon for aspiration of oral and esophageal secretions (more
effective for bleeding esophageal varices)
• Development of a single balloon Linton-Nachlas tube (for gastric varices).
• The airway should be protected by placement of an endotracheal tube.
• The use of water or oily contrast media to inflate the balloon is contraindicated.
• In the case of Sengstaken–Blakemore tube, the gastric balloon is inflated with 50 mL of air and after proper positioning, the gastric balloon inflated with 250 ml of air and plugged snug against the GE junction.
• If bleeding does not stop promptly, the gastric balloon may be inflated to at least a volume of 300 mL, or the esophageal balloon may be inflated to a pressure of 40 mm Hg.
• The Linton-Nachlas tube is inflated with 400-700 mL of air.
Complication
• MC complication of balloon tamponade is aspiration pneumonia.