The renal plasma flow (RPF) of a patient was to be estimated through the measurement of Para Amino Hippuric acid (PAH) clearance. The technician observed the procedures correctly but due to an error in the weighing inadvertently used thrice the recommended dose of PAH The RPF estimated is likely to be: [AI 03]
15 views
- False-high
- False-low (Correct Answer)
- False-high or false-low depending on the GFR
- Correct and is unaffected by the PAH overdose
Explanation
Correct Answer:-
B. False-low
(Ref. Ganong’s Physiology 24th edn. pp 651)
At high concentration of PAH, secretory
mechanism of PAH at PCT is saturated.
After complete saturation, clearance of PAH
falls.