<p>The most common cause of late implant failure is:</p>

14 views
  • Infection
  • Overloading
  • Poor bone quality
  • Peri-implantitis (Correct Answer)

Explanation

Peri-implantitis is an inflammatory condition leading to bone loss around osseointegrated implants. It is associated with poor oral hygiene, history of periodontitis, smoking, and occlusal overload. Prevention includes meticulous plaque control, regular follow-up, and professional cleaning. Early detection allows intervention with debridement, regenerative procedures, and antibiotics.