Shick test is designed to elicit
- Hypersensitivity to diphtheria toxin
- Presence of anti-toxin
- Immunity status
- All of the above (Correct Answer)
Explanation
Four types of the rations may occur in response to sick test:
i. Negative reaction: when blood serum contains more than 0.3units of anti-toxin/ml. Indicates that a person in immune to diphtheria
ii. Positive reaction: circumscribed red flush 10-50 mm in diameter within 24-48hours in the test arm, nil in the control arm. Indicates susceptibility to diphtheria
iii. Pseudo positive reaction: red flush not clearly circumscribed in both the arms. It is an allergic reaction interpreted as negative.
iv. Combined reaction: pseudo positive reaction in control arm and true positive reaction, interpreted as negative
Shick test has largely been replaced now by measurement of serum anti-toxin level by hemagglutination test.