Regarding sling procedure for Urodynamic Stress Incontinence (USI) all are correct except:
15 views
- Tension-free vaginal tape (TVT) is placed under the bladder neck to act as a hammock
- Voiding disorders are high with TVT (Correct Answer)
- The bladder may become overactive following the TVT procedure
- Transobturator tape (TOT) is placed underneath the midurethra
Explanation
(b). The incidence of voiding dysfunction seems to be lower with TVT.