Rectangular sewer: width 1 m, depth 1.5 m, slope 0.001, Manning n = 0.013. Q ≈ ?
15 views
- 1.8 m³/s (Correct Answer)
- 2.0 m³/s
- 1.5 m³/s
- 1.2 m³/s
Explanation
Use Manning formula: Q = (1/n) A R^(2/3) S^(1/2). Ensures sewer capacity meets design flow.