Prying forces in bolted steel connections occur mainly in:
6 views
- Lap joints with bolts in single shear
- Splices with bolts in double shear
- Tension connections in which the connected end plate or flange flexes (Correct Answer)
- Bearing-type connections loaded in pure shear
Explanation
When a flexible end plate or T-stub flange carries tension, it bends and bears against the connected member near its edges. This leverage adds a prying force to the bolt tension, and design must allow for it.