One man had 30 dB deafness in left ear with Weber test showing more sound in left ear and BC (Bone conduction] more on left side and normal hearing in right ear, his test can be summarized as:
- Webers test—left lateralized; Rinne test—right positive, BC>AC on left side (Correct Answer)
- Webers test—right lateralized; Rinne test—left positive, AC>BC on right side
- Webers test—left lateralized; Rinne test—false positive on right side, BC>AC on left side
- Webers left lateralized; Rinne test—equivocal, BC>AC on right side
Explanation
Answer: A. Webers test—left lateralized; Rinne test—right positive, BC>AC on left side
Webers test - left lateralized; Rinnes right positive; BC > AC on left side Ref. Dhingra, 6/e, p
22
Let us analyze each information provided in the question.
This man has deafness of 30 dB in left ear. Webers test is lateralized to left ear i.e. deaf ear
which means deafness is conductive type. (As in conductive deafness - Webers test is lateralized
to poorer ear). This means Rinne test should be negative on left side (as in conductive deafness -
Rinne test is negative). Ruling out options “b” and “d”. In the question it is given hearing is
normal on right side, so Rinne test will be positive on right side (because in case of normal
hearing - Rinne test is positive). In the question itself it is given, bone conduction is more on left
side. So option “a” is correct i.e.: Webers test - left lateralized, Rinne test - right positive and
BC>AC on left side.