Multiload device refers to :( BP : 1998)

33 views
  • First generation of IUCD
  • second generation of IUCD (Correct Answer)
  • OCP
  • Barrier contraceptive

Explanation

ans is b) Second generation of IUCD
The intrauterine device has been used throughout the world. During the last couple of decades, however, there has been a significant improvement in its design and content. The idea is to obtain maximum efficacy without increasing the adverse effects. The device is classified as open, when it has no circumscribed aperture of more than 5 mm so that a loop of intestine or omentum cannot enter and become strangulated, if accidentally, the device perforates through the uterus into the peritoneal cavity. Lippes loop, Cu T, Cu 7, Multiload and Progestasert are examples of open devices. If closed devices, like Grafenberg ring and Birnberg bow, accidentally enter the abdominal cavity, they have the potential of causing strangulation of the gut and hence are obsolete. The device may be non-medicated as Lippes loop or medicated (bioactive) by incorporating a metal copper, in devices like Cu T-200, Cu T-380A, Multiload-250, Multiload-375.

Copper T 200 — The widely used medicated device is Copper T 200 B. It carries 215 mm2 surface area of fine copper wire wound round the vertical stem of the device. Stem of the T-shaped device is made of a polyethylene frame. It has a polyethylene monofilament tied at the end of the vertical stem. These two threads are used for detection and removal. In spite of the copper being radiopaque, additional barium sulfate is incorporated in the device. The device contains 124 mg of copper. The copper is lost at the rate of about 50 µg per 24 hours during a period of 1 year. It is supplied inside a sterilized sealed packet. The device is to be removed after 4 years. Cu T 200 carries 200 mm2 surface area of wire containing 120 mg of copper and is removed after 3 years . Apart from the use of Cu T as a contraceptive , it is used following synechiolysis :
Cu T 380A — Cu T 380A carries a total 380 mm2 surface area of copper wire wound around the stem (314 mm2) and each copper sleeve on the horizontal arms (33 mm2). The frame contains barium sulfate and is radiopaque. Replacement is every 10 years.
Multiload Cu 250 — The device emits 60–100 µg of copper per day during a period of 1 year. The
device is to be replaced every 3 years.
Multiload–375 — The device is available in a sterilized sealed packet with an applicator. There is no
introducer and no plunger. It has a 375 mm2 surface area of copper wire wound around its vertical stem. Replacement is every 5 years .
Levonorgestrel intrauterine system (LNG-IUS) .This is a T-shaped device, with
polydimethylsiloxane membrane around the stem which acts as a steroid reservoir. Total amount of
levonorgestrel is 52 mg and is released at the rate of 20 µ g/day. This device is to be replaced every 7
years. Its efficacy is comparable to sterilization.
Progestasert — It is a progesterone (38 mg) containing IUD. Progestasert is no longer manufactured.
Lippes loop — It is a non-medicated open intrauterine device.
Mode of action: Mechanism of antifertility effect of all the IUDs is not yet clear. They act predominantly in the uterine cavity and do not inhibit ovulation.