Moist heat sterilization is more efficient than dry heat at a lower temperature mainly because:
- It kills microbes by oxidation of cell constituents
- It acts by toxic effect of elevated electrolytes
- It releases latent heat on condensation and coagulates proteins in the presence of water (Correct Answer)
- Steam does not penetrate wrapped instruments, preventing recontamination
Explanation
Moist heat kills microorganisms by denaturation and coagulation of proteins, including enzymes and structural proteins; the presence of water lowers the temperature required to coagulate proteins considerably. When saturated steam under pressure comes into contact with a cooler surface such as instruments, it condenses into water, releasing a large amount of latent heat (about 540 calories per gram) that rapidly heats the object. The condensation also creates a negative pressure that draws in more steam, ensuring good penetration of porous loads and wrapped packs. Thus autoclaving achieves sterilization at 121°C for 15 minutes or 134°C for 3-4 minutes. Dry heat, in contrast, kills microbes by oxidative damage of cell constituents, protein denaturation and toxic effects of elevated electrolyte levels; air is a poor conductor of heat, so a hot air oven needs 160°C for 2 hours or 180°C for 30 minutes. Dry heat is preferred for items that steam would damage or cannot penetrate, such as oils, powders and glassware, and causes less corrosion of sharp carbon-steel instruments. Air must be removed from autoclave chambers, since air pockets prevent steam contact and cause sterilization failure.