In tooth preparation for a porcelain laminate veneer, the recommended finish line design for the gingival margin is:
- A heavy chamfer located supragingivally (Correct Answer)
- A featheredge located at the gingival crest
- A shoulder with a 90-degree cavosurface angle
- A deep chamfer placed subgingivally
Explanation
For porcelain laminate veneers, the gingival margin preparation requires a balance of aesthetics, periodontal health, and restoration strength. The **recommended design is a supragingival or equigingival heavy chamfer (A). A chamfer (rounded internal line angle) provides adequate thickness of porcelain (typically 0.5 mm) to ensure strength and prevent fracture, while allowing a smooth transition to the tooth. Placing it supragingivally is preferred to maintain periodontal health and facilitate impression taking and finishing. A featheredge (B) provides minimal porcelain thickness, leading to weak edges and poor color blending. A shoulder (C) is unnecessarily aggressive for veneers and is used for full crowns. A deep subgingival chamfer (D) violates biological width, risks periodontal inflammation, and makes procedures more difficult. The goal is conservative preparation confined mostly to enamel.