In the context of maxillofacial trauma, a "guardian suture" is placed during the repair of which specific injury to prevent postoperative ectropion?

15 views
  • Zygomaticomaxillary complex (ZMC) fracture
  • Naso-orbito-ethmoidal (NOE) fracture
  • Orbital floor blowout fracture
  • Laceration of the lower eyelid (Correct Answer)

Explanation

A guardian suture, also known as a frost suture or temporary tarsorrhaphy suture, is specifically used during the repair of lacerations involving the lower eyelid or surgery in the periorbital region (e.g., ZMC fracture open reduction). Its purpose is to provide upward support to the lower lid during the healing phase to counteract gravitational pull and edema, thereby preventing postoperative ectropion (outward turning of the eyelid margin). The suture is typically placed from the gray line of the lower eyelid and taped to the forehead or cheek under slight upward tension. It is removed after 3-5 days. While ectropion is a risk with any periorbital trauma or surgery, the guardian suture is a specific technical step taken during soft tissue repair, not fracture repair per se. In NOE fractures, the concern is telecanthus (widening of the intercanthal distance), not ectropion. In orbital floor fractures, the concern is entrapment or enophthalmos.