In sensorineural hearing loss, webers test is lateralized to

15 views
  • Normal ear (Correct Answer)
  • Defective ear
  • Not lateralized
  • May alternate

Explanation

Ans. A. Weber test is lateralized to the unaffected or normal ear.
PURPOSE: Determination of a conductive vs.
a sensorineural hearing loss.
Strike tuning fork and place base in the center of the forehead or
the top of the head
Ask if the tone is louder in the left ear, the right ear or equally loud in
both ears due to the sound localization process,
In a patient with a unilateral conductive hearing loss, the sound
will be louder in the affected ear (airborne sounds mask bone
conduction in the normal ear; conductive loss prevents masking in
affected ear sound is perceived to be louder in affected ear)
In a patient with unilateral sensorineural hearing loss, the sound
is louder in the normal ear (no signal is transduced by the cochlea
on the affected side, therefore the sound is louder on the normal
side and is perceived to be coming from that side
In a normal person or a person with symmetrical hearing loss, it is
equally loud in both ears.
In other words, a normal patient, the Weber tuning fork sound is
heard equally loudly in both ears, with no one ear hearing the
sound louder than the other (lateralization). In a patient with
hearing loss, the Weber tuning fork sound is heard louder in one ear (lateralization) than the other.