In Roane's balanced force technique of canal preparation with hand files, the cutting action is achieved during which movement?
- Counter-clockwise rotation of at least 120 degrees with apical pressure (Correct Answer)
- Push-pull filing along the canal walls
- Withdrawal of the file with clockwise rotation
- Clockwise rotation of 90 degrees without apical pressure
Explanation
The balanced force technique, introduced by Roane, Sabala and Duncanson in 1985, was designed for triangular-cross-section files with non-cutting tips (Flex-R files) and allows preparation of curved canals with less transportation, ledging and zipping. It has three steps. First, the file is inserted and rotated clockwise about 90 degrees (a quarter turn) with light apical pressure, so that the flutes engage dentine and the file moves apically. Second, the file is rotated counter-clockwise by at least 120 degrees (up to 360 degrees) while sufficient apical pressure is applied to keep it at the same depth; this is the cutting stroke, during which the engaged dentine is sheared off. The apical force balances the tendency of the file to back out of the canal, hence the term "balanced force". Third, the file is rotated clockwise again to load dentine debris into the flutes and is withdrawn. Because the non-cutting tip follows the canal and the forces are balanced around the canal axis, the instrument remains centred, which helps maintain the original curvature. Other hand techniques include step-back (Mullaney), which prepares the apex first then flares coronally, step-down and crown-down (Marshall and Pappin), which prepare coronal portions first to reduce debris extrusion and improve irrigant penetration. Modern rotary and reciprocating nickel-titanium systems apply similar crown-down principles.