In meter bridge or Wheatstone bridge for measurement of resistance, the known and the unknown resistance are interchanged. The error so removed is
15 views
- end correction (Correct Answer)
- index error
- due to temperature effect
- random error
Explanation
ANS A In meter bridge experiment, it is assumed that the
resistance of the L shaped plate is negligible, but
actually it is not so. The error created due to this is
called end error. To remove this the resistance box
and the unknown resistance must be interchanged
and then the mean reading must be taken.