In a patient with systemic lupus erythematosus, which autoantibody titre characteristically rises during renal flares and falls with successful treatment, making it useful for monitoring disease activity?
- Anti-Smith antibody
- Anti-histone antibody
- Antinuclear antibody
- Anti-double-stranded DNA antibody (Correct Answer)
Explanation
Anti-dsDNA antibodies are highly specific for SLE (about 95%) and, unlike most other lupus antibodies, their titre tracks disease activity, particularly lupus nephritis. A rising anti-dsDNA titre with falling complement (C3, C4) is a classic predictor of a renal flare, because immune complexes containing dsDNA deposit in the glomeruli and activate complement. Anti-Smith antibody is the MOST specific marker for SLE (close to 100% specificity) but is present in only about 30% of patients and its level does not change with disease activity, so it is used for diagnosis, not monitoring. ANA is the most sensitive screening test (over 95%) but has poor specificity and a persistently positive result, so it is useless for follow-up. Anti-histone antibodies are the hallmark of drug-induced lupus (procainamide, hydralazine, isoniazid, minocycline), which typically spares the kidneys and CNS. Exam tip: sensitive = ANA, specific = anti-Sm, activity/nephritis = anti-dsDNA, drug-induced = anti-histone, neonatal lupus/heart block = anti-Ro (SSA).