Five days after placement of a Class II amalgam with poor isolation, the patient reports pain and the restoration is protruding. The alloy most likely:
- Was a zinc-containing alloy contaminated with moisture during condensation (Correct Answer)
- Was a zinc-free high-copper spherical alloy
- Was over-triturated
- Had excess mercury removed during condensation
Explanation
This is the classic picture of delayed (secondary) expansion. When a zinc-containing amalgam alloy (zinc more than 0.01%) is contaminated with moisture (saliva, blood) during trituration or condensation, zinc reacts with water to form zinc oxide and liberates hydrogen gas: Zn + H2O = ZnO + H2. The hydrogen accumulates within the restoration, building internal pressure that causes expansion beginning about 3-5 days after placement and continuing for months; expansion may exceed 4%. Clinically, this produces pressure pain, protrusion of the restoration from the cavity, marginal breakdown and increased microleakage and corrosion. Zinc-free alloys do not show this reaction, which is why they are preferred when moisture control is difficult. Over-trituration and removal of excess mercury generally reduce, not increase, dimensional change. Zinc is included in some alloys as a scavenger of oxygen during manufacture.