Duty = 1200 ha/cumec. Delta for base period 120 days ≈
13 views
- 0.86 m (Correct Answer)
- 1.2 m
- 1.5 m
- 2 m
Explanation
Relation: Delta (m) = (8.64 × B) / D = (8.64 × 120) / 1200 = 0.864 m ≈ 0.86 m Delta represents total water depth required by a crop. Duty represents area irrigated per unit discharge. These parameters are crucial in irrigation planning and canal design.