During laparoscopic procedures all are correct except:
16 views
- A volume of 3 litres of CO2 is sufficient for pneumoperitoneum
- A minimum intra-abdominal pressure of 15–18 mm Hg is required
- Transillumination of the abdominal wall for inferior epigastric vessels is needed before secondary trocar insertion
- Risk of significant complication during diagnostic procedure is about 10 in 1000 (Correct Answer)
Explanation
(d). Multicentre observational study mentioned the complication rate of 1.0 per 1000 for
minor and between 8 and 17 per 1000 for advanced procedures.