As per IS 456:2000, what partial safety factor for material strength is applied to reinforcing steel at the limit state of collapse?
10 views
- 1.50
- 1.15 (Correct Answer)
- 1.00
- 1.35
Explanation
IS 456:2000 specifies γm = 1.15 for steel and γm = 1.5 for concrete at the limit state of collapse. Hence the design strength of steel is fy/1.15 = 0.87fy.