An error of 1% in measuring the head of water over the crest of a rectangular weir, produces an error in the discharge which is equal to

29 views
  • 1.25%
  • 1.5% (Correct Answer)
  • 1.75%
  • 2.25%

Explanation

The discharge over a rectangular weir can be calculated using the following formula:

Q = CLH^(3/2)

Where Q is the discharge, C is the discharge coefficient, L is the width of the weir, and H is the head of water over the crest of the weir.

Differentiating both sides of the above formula with respect to H, we get:

dQ/dH = (3/2)CLH^(1/2)

Using the given percentage error in measuring the head of water over the crest of the weir, we can find the percentage error in the discharge as follows:

Percentage error in discharge = (Error in discharge / True discharge) x 100

= [(dQ/dH) x (Error in head / True head)] / (CLH^(3/2)) x 100

= [(3/2) x (Error in head / True head)] / 100

= (3/200) x (Error in head / True head)

Substituting the given values, we get:

Percentage error in discharge = (3/200) x (1/100)

= 0.015 or 1.5%

Therefore, an error of 1% in measuring the head of water over the crest of a rectangular weir produces an error in the discharge which is equal to 1.5%.