All are true about compliance of lung except ?
12 views
- Change in Volume per unit change in pressure
- Total Compliance is 0.2 L/cm
- measure of distensibility
- Decreased in emphysema (Correct Answer)
Explanation
Correct Answer - D Ans. D. Decreased in emphysema [Ref. Principles of medical physiology p.325,326 ; Ganong 24h/e p. 632] The change in volume per unit change in pressure is called 'compliance'. The total compliance of both lungs together in the normal adult human being is about 0.2 L/cm water. That is, every time the trans pulmonary pressure increases by 1 centimeter of water, the lung volume will expand 0.2 L (200 mI). Compliance is a measure of dispensability. Compliance is increased in emphysema.