According to Proffit, the optimum force for intrusion of a single tooth is:

18 views
  • 10–20 g (Correct Answer)
  • 35–60 g
  • 50–100 g
  • 70–120 g

Explanation

Proffit gives approximate optimum forces for each type of tooth movement: tipping 35–60 g, bodily movement (translation) 70–120 g, root uprighting 50–100 g, rotation 35–60 g, extrusion 35–60 g and intrusion only 10–20 g. Intrusion needs the lightest force because the force is concentrated in a small area at the root apex rather than spread along the periodontal ligament. A heavier intrusive force causes hyalinization at the apex and greatly increases the risk of apical root resorption. The 35–60 g range is correct for tipping, rotation and extrusion, 50–100 g for root uprighting, and 70–120 g for translation, where the load is spread over the whole root surface.