A water distribution system consists of a pipeline with a diameter of 200 mm and a length of 3 km. The pipeline is made of mild steel with a roughness coefficient of 0.02 mm. The flow rate through the pipeline is 10 liters per second. What is the frictional head loss in meters?

15 views
  • 14.1 m
  • 28.2 m (Correct Answer)
  • 42.3 m
  • 56.4 m

Explanation

Answer: b) 28.2 m

Explanation: The frictional head loss (hf) in a pipeline can be calculated using the Darcy-Weisbach equation:

hf = f * (L / D) * (V² / 2g)

where f is the friction factor, L is the length of the pipeline, D is the diameter of the pipeline, V is the flow velocity, and g is the acceleration due to gravity.

The flow velocity (V) can be calculated by dividing the flow rate (Q) by the cross-sectional area (A) of the pipeline. The cross-sectional area can be calculated using the formula for the area of a circle, A = π * (D/2)².

Thus, V = Q / A = (10 L/s) / (π * (0.2 m / 2)²) = 2.54 m/s.

The Reynolds number (Re) can be calculated using the formula Re = (ρ * D * V) / μ, where ρ is the density of water and μ is the dynamic viscosity of water. Here, we can assume that water is the fluid flowing through the pipeline. Thus, ρ = 1000 kg/m³ and μ = 0.001 Pa·s. Substituting the values, we get Re = (1000 kg/m³ * 0.2 m * 2.54 m/s) / 0.001 Pa·s = 508,000.

Using the Moody chart or Colebrook equation, we can find the friction factor (f) for the given flow conditions. For a mild steel pipe with a roughness coefficient of 0.02 mm, the friction factor can be found to be around 0.019.

Substituting the values into the Darcy-Weisbach equation, we get:

hf = 0.019 * (3 km / 0.2 m) *