A dentist notices that a light-cured composite restoration has inadequate depth of cure. The curing light has an intensity of 800 mW/cm² and was applied for 20 seconds. Which modification would MOST effectively improve the depth of cure?

18 views
  • Increasing curing time to 60 seconds
  • Using a flowable composite with lower filler content
  • Placing the composite in 1mm increments instead of 2mm (Correct Answer)
  • Applying the curing light from multiple angulations

Explanation

Light intensity decreases exponentially with depth due to absorption and scattering (Beer-Lambert law). Most composites cure only to 2-2.5mm depth. Increasing time cannot compensate for light that never penetrates to depth. Placing composite in 1mm increments ensures each layer receives adequate light intensity (≥400-500 mW/cm²) for thorough polymerization before adding the next layer.