A CBCT scan of an edentulous mandibular first molar site shows 12 mm of bone height from the alveolar crest to the superior border of the inferior alveolar canal, and adequate width. Respecting the commonly recommended safety margin, the maximum implant length that should be planned (including drill overpreparation) is about:

16 views
  • 13 mm
  • 12 mm
  • 10 mm (Correct Answer)
  • 8 mm, because a 4 mm safety zone is mandatory

Explanation

Injury to the inferior alveolar nerve is one of the most serious complications of implant surgery in the posterior mandible, causing paraesthesia, dysaesthesia or anaesthesia of the lower lip and chin, which can be permanent. To avoid it, a safety zone of at least 2 mm between the apex of the implant (and the drill tip) and the superior border of the inferior alveolar canal is recommended. Drills for many implant systems are slightly longer than the corresponding implant (by up to about 0.5-1.5 mm, because of the drill tip design), so the depth of drilling, not only the implant length, must be considered. In this case, the available bone height is 12 mm, and subtracting the 2 mm safety margin gives a maximum osteotomy depth of about 10 mm, so an implant of about 10 mm or slightly less (allowing for drill overpreparation) should be selected. A 12 mm or 13 mm implant would encroach on the canal. CBCT is preferred over panoramic radiography for measurement because panoramic images have variable vertical and horizontal magnification and do not show the buccolingual position of the canal; the canal often curves, and the lingual concavity of the posterior mandible (submandibular fossa) creates a risk of lingual cortical perforation and bleeding. Other measures include using drill stops, surgical guides, short or wide implants, and nerve lateralisation or vertical augmentation when bone height is insufficient.

Comments (0)

No comments yet. Be the first to comment!

Want to practice more?

Explore thousands of MCQs across every exam category on Exams Nepal.

Find More MCQs