A 65-year-old man known to have COPD is admitted with severe respiratory distress. What is the flow rate required to deliver 28% oxygen through a venturi mask?
- 4L/minute (Correct Answer)
- 6L/minute.
- 8L/minute
- 10L/minute.
Explanation
Correct Answer: A. 4L/minute.
The FiO2 delivered by venturi mask depends on the oxygen flow rate and
the amount of air entrained. The amount of air entrained depends on the
venturi mask adaptors. There are slits in the venturi mask adaptors, which
become smaller or larger depending on whether a high or lower FIO2 is
required. These slits are designed to entrain air from the environment.
Therefore, the set oxygen flow and the entrained air together meet the
inspiratory flow requirement of the patient. The average FiO2 (fraction of
inspired oxygen) delivered through venturi masks can be up to 5% above
the expected value.
Venturi masks provide a higher gas flow than the peak inspiratory flow rate
irrespective of the patient’s respiratory pattern. The FiO2 delivered
depends on the combination of venturi mask adaptor and the oxygen flow
rate. Therefore, just increasing the oxygen flow rate but keeping the
adaptor constant does not increase the FiO2 delivered.
Venturi adaptors and oxyqen flow rates are shown in table 1.
Table1. venturi adaptors and oxygen flow rates.
FiO2 Colour coding Oxygen flow L/min
0.24 Blue 2
0.28 White 4
0.31 Brown 6
0.35 Yellow 8
0.40 Red 10
0.60 Green 15