A 60-year-old female patient is scheduled to undergo a vaginal hysterectomy in the lithotomy position under general anaesthesia. The anticipated surgical duration is 75 minutes. Which one of the following characteristics of a ProSeal® LMA makes it most suitable over a classic LMA?

23 views
  • Presence of a flexible wire reinforced airway tube.
  • Better haemodynamic stability as compared to a classic LMA.
  • Reduced incidence of cough and sore throat in the postoperative period.
  • Improved airway seal, enabling positive pressure ventilation. (Correct Answer)

Explanation

Answer: D. Improved airway seal, enabling
positive pressure ventilation.
A Proseal® LMA (PLMA), like the classic LMA, consists of an airway tube, bowl and cuff. The airway tube is shorter but is reinforced to a similar calibre of an equivalent flexible LMA.
The modifications compared to the classic LMA are:
Larger and deeper bowl with no grille.
Posterior extension of the mask cuff.
Oesophageal drain tube running parallel to the airway tube and exiting at the mask tip.
Integral silicone bite block.
Anterior pocket for seating an introducer or finger during insertion.
When the PLMA is correctly positioned, the cuff tip lies behind the cricoid cartilage at the origin of the oesophagus. In the event of regurgitation, the liquid and semi-solid contents may be aspirated through the drain port. The haemodynamic response to insertion or removal of a PLMA is the same as that for a classic LMA. The posterior cuff and the increased bulk of the PLMA mask together substantially increase the pharyngeal leak pressure and reduce the risk of gastric insufflation during positive
pressure ventilation. The airway tube of the PLMA is shorter than the classic LMA, but is wire-reinforced and of similar calibre to the flexible LMA. Airway resistance is 20% greater than the classic LMA. The patient in the above mentioned scenario would need to be in the lithotomy position with anaesthetic duration of more than an hour and, hence, controlled
ventilation is preferable. The aspiration risk is not high as this is an elective procedure in a fit and well patient. An airway device which can facilitate
controlled ventilation with minimal leak and risk of gastric insufflation, such as a PLMA, would be the right choice for this procedure.