A 40-year-old ASA 1 male patient with a body mass index of 28 is undergoing a complex orthopaedic procedure on the left forearm lasting for 8 hours. The most appropriate reason for choosing invasive arterial blood pressure monitoring over automated noninvasive blood pressure measurement in this patient is:
20 views
- Automated non-invasive blood pressure monitoring would be inaccurate in this patient.
- Automated blood pressure monitoring is likely to result in ulnar nerve injury
- Monitoring invasive blood pressure ensures adequate perfusion pressure
- Automated non-invasive blood pressure monitoring for 8 hours can result in distal oedema of the limb. (Correct Answer)
Explanation
Correct Answer: D. Automated non-invasive blood
pressure monitoring for 8 hours can result in
distal oedema of the limb.
Automated non-invasive blood pressure measurement using a correctly
sized cuff is as accurate as invasive measurement. Also, correct
positioning with the lower border above the elbow joint prevents any ulnar
nerve injury. Delivering adequate perfusion to any organ can be monitored
by non-invasive blood pressure measurement. Hypotension can be
detected early with the use of shorter cycling times. However, such
frequent recordings over a prolonged time predisposes to distal oedema
of the limb.