A 33-year-old woman with a refraction of −9.00 +3.00×90 OD at vertex distance 10 mm and keratometry readings of 46.00@90/43.00@180 is fit for a rigid gas-permeable (RGP) contact lens 1 D steeper than flattest K. What power lens is required?

30 views
  • −5.00 D
  • −6.00 D
  • −7.00 D (Correct Answer)
  • −8.00 D

Explanation

Ans C −7.00 D—step 1: change refraction to minus cylinder
form (because the tear lake negates the minus cylin-
der) and use this sphere (−6.00); step 2: adjust to zero
vertex distance (−6+0.01[−6]2 =−5.64); step 3: adjust
for tear lens (SAM-FAP rule) (add −1.00=−6.64)