A 33-year-old woman with a refraction of −9.00 +3.00â•›×â•›90 OD at vertex distance 10╯mm and keratometry readings of 46.00@90/43.00@180 is fit for a rigid gas-permeable (RGP) contact lens 1 D steeper than flattest K. What power lens is required?
15 views
- −5.00 D
- −6.00 D
- −7.00 D (Correct Answer)
- −8.00 D
Explanation
Correct Answer:-
C. −7.00 D
step 1: change refraction to minus cylinder
form (because the tear lake negates the minus cylinder) and use this sphere (−6.00);
step 2: adjust to zero
vertex distance (−6+0.01[−6]2 =−5.64);
step 3: adjust for tear lens (SAM-FAP rule) (add −1.00=−6.64)