A 32-year-old male with recurrent deep vein thromboses is found to have a point mutation leading to factor V resistance to cleavage by protein C. The likely mutation is:
17 views
- Factor V Leiden (Arg506Gln) (Correct Answer)
- Prothrombin G20210A mutation
- Antithrombin deficiency
- Protein C deficiency due to liver failure
Explanation
Factor V Leiden (Arg506Gln) causes APC resistance leading to hypercoagulability and recurrent DVTs. Prothrombin G20210A increases prothrombin levels; antithrombin/protein C deficiencies are separate causes.