ENT MCQs for Medical NMCLE / Loksewa / MDMS Exams – Page 7
1,014 ENT multiple-choice questions with answers and explanations, from the ExamsNepal question bank for Medical NMCLE / Loksewa / MDMS Exams. Try each question first, then open the answer to check your reasoning.
In ExamsNepal mock tests, students answer 62% of ENT questions correctly (3,885 answers).
Preparing for MECEE-PG - MD/MS Entrance, NMC Licensing Examination (NMCLE) or NMC Special Examination? See the exam pattern, syllabus and free mock tests.
121. In facial nerve palsy of right side, Stapedial reflex will be absent on:
- A. Right side
- B. Left side
- C. Both sides
- D. Not absent
Discuss this questionShow answer & explanation
Answer: A. Right side
Correct Answer :A.Right side
Facial nerve forms the efferent of stapedial reflex, so in facial nerve palsy of right side, the stapedial reflex is absent on right
side only.
Remember
VIII N forms the afferent of the reflex ∴ in VIII N lesions, stapedial reflex is absent in both ipsilateral and contralateral ears.122. In monaural diplacusis the lesion is in the:
- A. Cochlea
- B. Auditory nerve
- C. Brainstem
- D. Cerebrum
Discuss this questionShow answer & explanation
Answer: A. Cochlea
Correct Answer :A. Cochlea
Ref. Tuli 1/e, p 114
Subjective feeling of diplacusis, hyperacusis or fullness in the ear occurs in cochear pathology or cohlear, sensorineural hearing
loss (SNHL)123. Tuning fork of 512 FPS is used to test the hearing because it is:
- A. Better heard
- B. Better felt
- C. Produces over tones
- D. Not heard
Discuss this questionShow answer & explanation
Answer: A. Better heard
Correct Answer :A. Better heard
Ref. Tuli 1/e, p 28
Tuning fork tests can be done with tuning forks of different frequencies like 128, 256, 512, 1024, 2018 and 4096 Hz but most
commonly used is 512 Hz because
y “Tests are done with various tuning forks, but 512 Hz is the most commonly used as it has longer tone decay and sound is
quite distinct from ambient noise.”
y Forks of lower frequencies produce a sense of bone vibration while those of higher frequency have a shorter decay time
and therefore not commonly used124. . Gelle’s test is done in:
- A. Senile deafness
- B. Traumatic deafness
- C. Osteosclerosis
- D. Serous otitis media
Discuss this questionShow answer & explanation
Answer: C. Osteosclerosis
Correct Answer :C. Osteosclerosis
Ref. Dhingra, 6/e, p 22
Gelle’s test was once a popular test to find out stapes fixation in otosclerosis, but now it has been superseded by tympanometry.
In this test, bone conduction is tested and at the same time Siegel’s speculum compresses the air in the meatus.125. Rinne’s test is negative if minimum deafness is:
- A. 15–20 dB
- B. . 25–30 dB
- C. 35–40 dB
- D. 15–50 dB
Discuss this questionShow answer & explanation
Answer: A. 15–20 dB
Correct Answer :A. 15 – 20 dB
Ref. Dhingra, 6/e, p 22
As discussed in the text in Rinnies test—air conduction of the ear is compared with its bone conduction.126. Rinne’s test is positive in:
- A. Chronic suppurative otitis media
- B. Normal individual
- C. Wax inear
- D. Otomycosis
Discuss this questionShow answer & explanation
Answer: B. Normal individual
Correct Answer :B. Normal individual
Ref. Dhingra 6/e, p 22
Rinne’s test is positive i.e. air conduction > bone conduction
It is seen in:
a. Normal individuals (Ans 9)
b. In case of sensorineural hearing loss (SNHL)
Amongst the options given in Q.8 only presbyacusis causes SNHL and therefore gives positive Rinne test
Presbycusis: It is sensorineural hearing loss associated with physiological aging process in the ear. It manifests at 65 years of age.127. Weber test is best elicited by:
- A. Placing the tuning fork on the mastoid process and comparing the bone conduction of the patient with that of the examiner
- B. Placing the tunning fork on the vertex of the skull and determining the effect of gently occluding the audtitory canal on the thereshold of low frequencies
- C. Placing the tuning fork on the mastoid process and comparing the bone conduction in the patient
- D. Placing the tuning fork on the forehead and asking him to report in which ear he hears it better
Discuss this questionShow answer & explanation
Answer: D. Placing the tuning fork on the forehead and asking him to report in which ear he hears it better
Correct Answer :D. Placing the tuning fork on the forehead and asking him to report in which ear he hears better128. What should be the least hearing loss for Weber test to lateralize:
- A. 5 dB
- B. 10 dB
- C. 15 dB
- D. 20 dB
Discuss this questionShow answer & explanation
Answer: A. 5 dB
Correct Answer :A.5 dB
As discussed in the text in Weber’s Test
In normal Individuals – No lateralization of sound occurs as Bone conduction of both ears in normal and equal.
In conductive deafness – Lateralization of sound occurs to the diseased ear (Ans 12)
In SNHL – Lateralization of sound occurs to the better ear.129. A middle-aged women presented with right sided hearing loss, Rinne’s test shows positive result on left side and negative result on right side Weber’s test showed lateralization to left side, diagnosis is:
- A. Right sided conductive deafness
- B. Right sided sensorineural deafness
- C. Left sided sensorineural deafness
- D. Left sided conductive deafness
Discuss this questionShow answer & explanation
Answer: B. Right sided sensorineural deafness
Correct Answer :B.Right sided sensorineural deafness
Ref. Dhingra 6/e, p 22, Table 4.1
Rinne’s Test
Negative on right side means either there is:
Conductive deafness of Right side or
Severe SNHL on right side (leading to false negative Rinne test)
To differentiate between the 2 conditions: Let us see the result of Weber’s test:
Patient is complaining of decreased hearing in right ear and Weber’s test is lateralized to left ear (as stated in the question) i.e.
to the better ear.
As discussed in the text: Weber’s test is lateralized to the better ear in case of SNHL.
So, diagnosis is right sided severe SNHL.
Remember: If Rinne’s test is negative and Weber’s test shows lateralization toward healthy side, it indicates severe SNHL130. One man had 30 dB deafness in left ear with Weber test showing more sound in left ear and BC (Bone conduction] more on left side and normal hearing in right ear, his test can be summarized as:
- A. Weber’s test—left lateralized; Rinne test—right positive, BC>AC on left side
- B. Weber’s test—right lateralized; Rinne test—left positive, AC>BC on right side
- C. Weber’s test—left lateralized; Rinne test—false positive on right side, BC>AC on left side
- D. . Weber’s left lateralized; Rinne test—equivocal, BC>AC on right side
Discuss this questionShow answer & explanation
Answer: A. Weber’s test—left lateralized; Rinne test—right positive, BC>AC on left side
Correct Answer :A. Weber’s test - left lateralized; Rinne’s right positive; BC > AC on left side
Ref. Dhingra, 6/e, p 22
Let us analyze each information provided in the question.
y This man has deafness of 30 dB in left ear.
y Weber’s test is lateralized to left ear i.e. deaf ear which means deafness is conductive type. (As in conductive deafness - Weber’s
test is lateralized to poorer ear).
This means Rinne test should be negative on left side (as in conductive deafness - Rinne test is negative). Ruling out options “b”
and “d”.
In the question it is given hearing is normal on right side, so Rinne test will be positive on right side (because in case of normal
hearing - Rinne test is positive).
In the question itself it is given, bone conduction is more on left side.
So option “a” is correct i.e.:
Weber’s test - left lateralized, Rinne test - right positive and BC>AC on left side.131. . A 38-year-old male presented with a suspected diagnosis of suppurate labyrinthitis. A positive Rinne’s test and positive fistula test was recorded on initial examination. The patient refused treatment, and returned to the emergency department after 2 weeks complaining of deafness in the affected ear. On examination, fistula test was observed be negative. What is the likely expected finding on repeating the Rinne test.
- A. True positive Rinne’s test
- B. . False positive Rinne’s test
- C. True negative Rinne’s test
- D. False negative Rinne’s test
Discuss this questionShow answer & explanation
Answer: D. False negative Rinne’s test
Correct Answer :D. False negative Rinne’s test
Ref. Dhingra, 6/e, p22
In the above question: Patient was suffering from suppurative labyrinthitis which was not treated and led to total loss of hearing
i.e. severe SNHL.
In severe SNHL: Rinne’s test is false negative and because labyrinth is dead. Fistula test is negative.
False negative Rinne test as explained earlier occurs in case of severe SNHL because patient does not perceive any sound of tuning
fork by air conduction but responds to bone conduction due to intracranial transmission of sound from opposite healthy ear.
Fistula Test
The basis of this test is to induce nystagmus by producing pressure changes in the external canal which are then transmitted to the
labyrinth. Stimulation of the labyrinth results in nystagmus and vertigo. Normally the test is negative because the pressure changes
in the EAC cannot be transmitted to the labyrinth.
Positive Fistula Test is seen in:
y Erosion of horizontal semicircular canal (Cholesteatoma or fenestration operation)
y Abnormal opening in oval window (post stapedectomy fistula) or round window (rupture of round window).
A positive fistula test also implies that the labyrinth is still functioning.
y False-negative fistula test: Dead labyrinth, cholesteatoma covering site of fistula.
y False-positive fistula test (Positive fistula test without Fistula): Congenital syphilis, 25% cases of Meniere’s disease (Hennebert’s sign.)132. The “O” sign in a pure tone audiogram indicates:
- A. Air conduction of right ear
- B. Air conduction of left ear
- C. Bone conduction of right ear
- D. Bone conduction of left ear
Discuss this questionShow answer & explanation
Answer: A. Air conduction of right ear
Correct Answer :A. Air conduction of right ear.
For symbols used in auditometry—See the preceeding text133. Which of the following test assesses resistance in middle ear
- A. Pure tone audiometry
- B. Impendence audiometry
- C. Caloric test
- D. BERA (Brainstem evoked response audiometry)
Discuss this questionShow answer & explanation
Answer: B. Impendence audiometry
Correct Answer :B. Impedence audiometry.
Ref. Dhingra 6/e, p 24; Current Otolaryngology 2/e, p 601
Impedance Audiometry
1. It is an objective test for hearingQ
2. It is very useful in children for assessing the hearing loss. Q
3. It consists of tympanometry and acoustic reflex
Tympanometry is a measure of the condition of the middle ear at the level of tympanic membrane.
NOTE
y For infants and neonates, tympanograms obtained using a 220 Hz probe may erroneously appear normal.
∴ a higher frequency probe tone (660 or 1000 Hz) must be used - (Current Otolaryngology 2nd/ed p601)134. High frequency audiometry is used in:
- A. Otosclerosis
- B. Ototoxicity
- C. Non-organic hearing loss
- D. Meniere’s disease
Discuss this questionShow answer & explanation
Answer: B. Ototoxicity
Correct Answer :B.Ototoxicity
Ref. Scott Brown 7/e Vol. 3, p 3572; Audiology by Ross J. Roeser, Michael Valente,
Holly Hosford-Dunn 2/e, p 242; Ototoxicity by Peter S. Roland, John A. Rutka, p 154
High frequency audiometry
Conventional audiometry tests frequencies between 0.25 kHz - 8 kHz, whereas high frequency audiometry tests in the region of
8 kHz-20 kHz. Some environmental factors, such as ototoxic medication like aminoglycosides and noise exposure, appear to be more
detrimental to high frequency sensitivity than to that of mid or low frequencies. Therefore, high frequency audiometry is an effective
method of monitoring losses that are suspected to have been caused by these factors. It is also effective in detecting the auditory
sensitivity changes that occur with aging135. Flat and dome-shaped graph in tympanogram is found in:
- A. Otosclerosis
- B. Ossicular discontinuity
- C. TM perforation
- D. Middle ear fluid
Discuss this questionShow answer & explanation
Answer: D. Middle ear fluid
Correct Answer :D. Middle ear fluid
Ref. Dhingra 6/e, p 24
y Flat (or dome-shaped) tympanogram is type B curve of tympanogram which is seen in case of fluid in middle ear.
y Fluid (i.e. pus) is seen in case of ASOM and sterile non purulent effusion is seen in case of serous otitis media. So, in both these
conditions flat tympanogram/type B tympanogram will be seen.136. In osteogenesis imperfecta, the tympanogram is:
- A. Flat
- B. Noncompliance
- C. High-compliance
- D. Low-compliance
Discuss this questionShow answer & explanation
Answer: D. Low-compliance
Correct Answer :D. Low compliance
Ref. Scott Brown 7/e Vol. 3, p 3458, Dhingra 6/e, p 87
This is a very interesting question – They are testing our knowledge as well as application ability137. A young man presents with an accident leading to loss of hearing in right ear. On otoscnormal cochlear reserve. Which of the following will be the like tympanometry finding:opic examination, the tympanic membrane was intact pure tone audiometry that shows an air-bone gap of 55 dB in the right with
- A. As type tympanogram
- B. Ad type tympanogram
- C. Ad type tympanogram
- D. C type tympanogram
Discuss this questionShow answer & explanation
Answer: B. Ad type tympanogram
Correct Answer :B.Ad type tympanogram
Ref. Dhingra 5/e, p 27, 30 and 34
This is also a very interesting question:
y The question says. Pure tone audiometry shows an air bone gap of 55 dB in the right ear with normal cochlear reserve.
y The air-bone gap in pure tone audiometry is a measure of total conductive deafness.
y Hence – it means there is a conductive deafness of 55 dB in the right ear.
y Next the question says – Patient has intact tympanic membrane so we have to look for a cause of this 55 dB conductive deafness.
Average hearing loss seen in different lesions of conductive apparatus Ref. Dhingra 5th/ed p34
1. Complete obstruction of ear canal 30 dB
2. Perforation of tympanic membrane 10–40 dB
3. Ossicular interruption with intact drum 54 dB
4. Ossicular interruption with perforation 10–25 dB
5. Closure of oval window 60 dB
As is clear from above table – with tympanic membrane intact and a hearing loss of 55 dB is seen if ossicular chain is disrupted.
Hence– it is a case of ossicular discontinuity.
Tympanogram seen in ossicular discontinuity is a high compliance tympanogram i.e. Ad tympanogram.138. Which is the investigation of choice in assessing hearing loss in neonates?
- A. Impedance audiometry
- B. Brainstem evoked response audiometry (BERA)
- C. . Free field audiometry
- D. Behavioral audiometry
Discuss this questionShow answer & explanation
Answer: B. Brainstem evoked response audiometry (BERA)
Correct Answer :B. Brainstem evoked response audiometry (BERA)139. In normal adult wave v is generated from:
- A. Cochlear nucleus
- B. Superior olivary complex
- C. Lateral lemniscus
- D. Inferior colliculus
Discuss this questionShow answer & explanation
Answer: C. Lateral lemniscus
Correct Answer :C.. Lateral lemniscus
Ref. Dhingra 6/e, p 27, Scott Brown 7/e Vol. 3, p 3283
In normal persons during BERA testing, 7 waves are produced in the first 10 milli second
The 1st, 3rd and 5th wave are the most stable and are used in measurements
These waves are studied for:
– Absolute latency
– Inter wave latency (between wave I and V)
– Amplitude140. Test of detecting damage to chochlea
- A. Caloric test
- B. Weber test
- C. Rinne’s test
- D. ABC test
Discuss this questionShow answer & explanation
Answer: D. ABC test
Correct Answer :D. ABC test
Ref. Dhingra, 6/e, p 22
As discussed earlier absolute bone conduction test is a tuning fork test in which bone conduction of the patient is compared
with BC of the examiner after occluding the external auditory meatus of both patient and examiner
Bone conduction is a measure of cochlear function.
Hence, ABC test is used to detect damage to cochlea.
Rinne’s test
— Measure air conduction
Weber’s test
Caloric test – assesses vestibular function