Community Medicine MCQs for Medical NMCLE / Loksewa / MDMS Exams – Page 39
1,948 Community Medicine multiple-choice questions with answers and explanations, from the ExamsNepal question bank for Medical NMCLE / Loksewa / MDMS Exams. Try each question first, then open the answer to check your reasoning.
In ExamsNepal mock tests, students answer 60% of Community Medicine questions correctly (9,208 answers).
Preparing for MECEE-PG - MD/MS Entrance, NMC Licensing Examination (NMCLE) or NMC Special Examination? See the exam pattern, syllabus and free mock tests.
761. ‘Cooling Power’ of air is measured by:
- A. Kata thermometer
- B. Hygrometer
- C. Anemometer
- D. Sling’s Psychrometer
Discuss this questionShow answer & explanation
Answer: A. Kata thermometer
Correct Answer :- A. Kata thermometer
[Nowadays its only used to meaure low air velocity]
[Ref. Park 23/e p732, 747]762. The mechanical system in which fresh air is blown into the room by centrifugal fans so as to create positive pressure and displace the vitiated air is termed as:
- A. Balanced ventilation
- B. Air conditioning
- C. Exhaust ventilation
- D. Plenum ventilation
Discuss this questionShow answer & explanation
Answer: D. Plenum ventilation
Correct Answer :- D. Plenum ventilation
[Ref. Park 23/e p739]763. The mean radiant temperature is measured by:
- A. Dry bulb thermometer
- B. Wet bulb thermometer
- C. Six’s maximum and minimum thermometer
- D. Globe thermometer
Discuss this questionShow answer & explanation
Answer: D. Globe thermometer
Correct Answer :- D. Globe thermometer
[Ref. Park 23/e p732]
• Instruments used in Air temperature:
Instrument
Dry bulb thermometer
Wet bulb thermometer
Maximum thermometer
Minimum thermometer
Six’s maximum and minimum thermometer
Silvered thermometer
Globe thermometer
Wet Globe thermometer
Kata thermometer
Measures
Air temperature
Air temperature
Air temperature
Air temperature
Air temperature
Air temperature
Mean radiant temperature
Environmental heat
Cooling power of Air; Low air velocities764. Global warming true is:
- A. CO<sub>2</sub> is a major greenhouse gas
- B. Stratosphere ozone layer is harmful
- C. CFC increases stratosphere ozone layer
- D. Kyoto protocol called for 20% reduction in green- house emissions
Discuss this questionShow answer & explanation
Answer: A. CO<sub>2</sub> is a major greenhouse gas
Correct Answer :- A. CO2
is a major greenhouse gas
[Ref. Wikipedia]
GREENHOUSE GASES
• Water vapour (Highest contribution)
• Carbondioxide (Second highest contribution)
• Methane
• Ozone
– Ozone layer: Is beneficial as it cuts down UV transmission
• CFCs depletes ozone layer765. Which of the following is not a source of Indoor Air Pollution?
- A. Carbon monoxide
- B. Nitrogen dioxide
- C. Radon
- D. Mercury vapour
Discuss this questionShow answer & explanation
Answer: D. Mercury vapour
Correct Answer :- D. Mercury vapour
[Ref. K. Park 23/e p735-736]
Sources of Indoor Air Pollution: (Mnemonic: C MORON SCARF)
Indoor air pollutant
Respirable particles
Carbon monoxide
Nitrogen dioxide
Sulphur dioxide
Carbon dioxide
Formaldehyde
Organic vapours (benzene, toulidine)
Ozone
Radon & daughters
Asbestos
Mineral fibres
Sources
Tobacco smoke, Stove, Aerosols
Combustion equipment, Stove, Gas heaters
Gas cookers, Cigarettes
Coal combustion
Combustion, Respiration
Particle board, Carpet adhesives, Insulation
Solvents, Adhesives, Resins, Aerosols
Electric arcing, UV light
Building materials
Insulation, Fire-proofing
Appliances766. Indoor air pollution does not cause:
- A. Chronic lung disease
- B. Pregnancy problems
- C. Childhood pneumonia
- D. Neuro-developmental problems
Discuss this questionShow answer & explanation
Answer: D. Neuro-developmental problems
Correct Answer :- D. Neuro-developmental problems
[Ref. K Park 23/e p735-736]
Effects of indoor air pollution
• Acute respiratory tract infections (Pneumonias)
• Chronic lung disease
• Lung cancers in adults
• Adverse pregnancy outcomes (Especially stillbirths)767. Which of the following is non-natural gas causing green house effect?
- A. Carbon dioxide
- B. Methane
- C. Ozone
- D. CFCs
Discuss this questionShow answer & explanation
Answer: D. CFCs
Correct Answer :- D. CFCs
[Ref. Global Change of Planet Earth OECD, p48]768. Acceptable level for physical comfort:
- A. Corrected effective temperature 77-80ºF
- B. Corrected effective temperature 70-76ºF
- C. Corrected effective temperature 80-81ºF
- D. Corrected effective temperature >82ºF
Discuss this questionShow answer & explanation
Answer: A. Corrected effective temperature 77-80ºF
Correct Answer :- A. Corrected effective temperature 77-80ºF
[Ref. K Park 23/e p732]769. Which agency monitors air quality in India?
- A. Central Research Institute
- B. Ministry if health and Family Welfare
- C. National Environmental Engineering Research Institute
- D. Central Pollution Control Board
Discuss this questionShow answer & explanation
Answer: D. Central Pollution Control Board
Correct Answer :- D. Central Pollution Control Board
[Ref. K Park 23/e p737]770. In winter, water vapours and pollutants comes to lie in the lowermost layer of atmosphere by:
- A. Acid rain
- B. Green house effect
- C. Temperature inversion
- D. Ocean effect
Discuss this questionShow answer & explanation
Answer: C. Temperature inversion
Correct Answer :- C. Temperature inversion
[Ref. Encyclopedia of Climate and Weather by Schneider, Root & Mastrandrea, 2/e (Volume 3) p392]771. At which level of heat stress index it is not possible to work comfortably causing threat to health:
- A. 20 - 40
- B. 40 - 60
- C. 60 - 80
- D. 80 – 100
Discuss this questionShow answer & explanation
Answer: B. 40 - 60
Correct Answer :- B. 40 – 60
[Ref. Park 23/e p747]
Heat Stress Index (HSI)
HSI %
0
10-30
40-60
70-90
100
>100
Consequence of 8 hour exposure
No thermal strain
Mild-Moderate heat stress, Minimal impairment in work
Severe heat stress, Threat to health if not fit
Very severe heat stress, only few can sustain it
Maximum heat stress, only young fit acclimatized can sustain it
Varying degress of stress due to hyperthermia772. Which of the following is not a feature of heat stress?
- A. Hyperpyrexia
- B. Syncope
- C. Cramps
- D. Numbness
Discuss this questionShow answer & explanation
Answer: D. Numbness
Correct Answer :- D. Numbness
[Ref. Park 23/e p747-748]
EFFECTS OF HEAT STRESS
• Heat stroke: Body temperature >110ºF, Delirium, Convulsions, Absence of sweating
• Heat hyperpyrexia
• Heat exhaustion
• Heat cramps
• Heat syncope773. Number of air changes in a drawing room per hour should be at least:
- A. 2-3
- B. 3-4
- C. 4-5
- D. 5-6
Discuss this questionShow answer & explanation
Answer: A. 2-3
Correct Answer :- A. 2 – 3
[Ref. Park 21/e p681, Park 22/e p685]774. Number of air changes in one hour in a work room should be at least:
- A. 2-3
- B. 3-4
- C. 4-6
- D. 5-7
Discuss this questionShow answer & explanation
Answer: C. 4-6
Correct Answer :- C. 4 – 6
[Ref. Park 21/e p681, Park 22/e p685]775. Acceptable level for physical comfort:
- A. Corrected effective temperature 79°F
- B. Corrected effective temperature 70-76°F
- C. Corrected effective temperature 80-81°F
- D. Corrected effective temperature > 82°F
Discuss this questionShow answer & explanation
Answer: A. Corrected effective temperature 79°F
Correct Answer :- A.Corrected effective temperature 79°F
[Ref. Park 23/e p732]776. In Indoor air pollution, carbon monoxide is produced by:
- A. Combustion equipment
- B. Stove
- C. Gas heaters
- D. All of the above
Discuss this questionShow answer & explanation
Answer: D. All of the above
Correct Answer :- D. All of the above
[Ref. Park 23/e p735-736]777. Relative humidity is determined by:
- A. Kata thermometer
- B. Anemometer
- C. Sling psychrometer
- D. Gardbad apparatus
Discuss this questionShow answer & explanation
Answer: C. Sling psychrometer
Correct Answer :- C. Sling psychrometer
[Ref. Park 23/e p749]778. Whispering produces a sound of:
- A. 20-30 dB
- B. 30-40 dB
- C. 40-50 dB
- D. 50-60 dB
Discuss this questionShow answer & explanation
Answer: A. 20-30 dB
Correct Answer :- A. 20-30 dB
[Ref. K. Park 23/e p742]
• Human ear is sensitive to sound frequency: 20 – 20,000 Hz
• Daily maximum tolerable sound level to human ear (without substantial damage to their hearing): 85 – 90 dB
– Auditory fatigue appears in: 90 dB region (greatest at 4000 Hz)
• Sound level above which tympanic membrane rupture (permanent mechanical damage): 150 – 160 dB
• Sound levels of some noises:
– Whisper: 20 – 30 dB
– Normal conversation: 60 – 70 dB
– Mechanical damage: 150 – 160 dB (e.g Jet taking off)
• Acceptable noise levels: expressed in dB (A), sound pressure levels conforming to weighting curve (A)
Environment
Residential
Commercial
Industrial
Educational
Hospitals
Place
Bed room
Living room
Office
Conference
Restaurants
Workshop
Laboratory
Class room
Library
Wards
Acceptable noise level dB (A)
25
40
35 – 45
40 – 45
40 – 60
40 – 60
40 – 50
30 – 40
35 – 40
20 – 35
Also Remember
• 20th century has been described as ‘Century of noise’
• Basic instruments used in studies of noise:
Instrument
Sound Level Meter
Octave Band Frequency Analyser
Audiometer
Use
Measures intensity of sound in dB or dB(A)
Shows ‘sound spectrum’, characteristic (pitch)
Measures hearing ability
• Most Temporary Hearing loss occurs in the frequency range: 4000-6000 Hz.
779. Recommended illumination range for regular work is _______ foot-candles:
- A. 6-12
- B. 25-50
- C. 50-75
- D. 75-100
Discuss this questionShow answer & explanation
Answer: A. 6-12
Correct Answer :- A. 6-12
[Ref. Park 23/e p739]
• Basic minimum illumination for satisfactory vision: 15 – 20 foot candles780. The optimum floor space recommended per adult person in a dwelling place is:
- A. 50–100 sq.ft.
- B. 101–450 sq.ft.
- C. 151–200 sq.ft.
- D. 201–250 sq.ft.
Discuss this questionShow answer & explanation
Answer: A. 50–100 sq.ft.
Correct Answer :- A. 50—100 sq.ft.
[Ref. Park 23/e p752]
• Recommend per capita space in urban houses: 50-100 sq-ft.
# Also Remember
• Accepted standards of overcrowding:
– Persons per room:
No. of rooms
1 rooms
2 rooms
3 rooms
4 rooms
5 rooms
(additional 2 for each further room)
Maximum no. of persons
2 persons
3 persons
5 persons
7 persons
10 persons
Floor space per person: Child between 1 – 10 years is counted as ½ unit; infant is not counted
Floor space
> 110 sq. ft.
90 – 110 sq. ft.
70 – 90 sq. ft.
50 – 70 sq. ft.
< 50 sq. ft.
Maximum no. of persons
2 persons
1½ persons
1 person
½ person
Nil
– Sex separation: Overcrowding is said to exist if two persons over 9 years of age, not husband and wife, of opposite sexes are obliged to sleep in the same room
• Recommended spaces:
– Floor space per person in a house: minimum 90 – 110 sq. ft.
– Floor area per student in a class: > 10 sq. ft.
– Space per worker in a factory (The Factory Act, 1948): >500 cu. ft.