Community Medicine MCQs for Medical NMCLE / Loksewa / MDMS Exams – Page 39

1,948 Community Medicine multiple-choice questions with answers and explanations, from the ExamsNepal question bank for Medical NMCLE / Loksewa / MDMS Exams. Try each question first, then open the answer to check your reasoning.

In ExamsNepal mock tests, students answer 60% of Community Medicine questions correctly (9,208 answers).

Preparing for MECEE-PG - MD/MS Entrance, NMC Licensing Examination (NMCLE) or NMC Special Examination? See the exam pattern, syllabus and free mock tests.

  1. 761. ‘Cooling Power’ of air is measured by:

    • A. Kata thermometer
    • B. Hygrometer
    • C. Anemometer
    • D. Sling’s Psychrometer
    Show answer & explanation

    Answer: A. Kata thermometer

    Correct Answer :- A. Kata thermometer

    [Nowadays its only used to meaure low air velocity]

    [Ref. Park 23/e p732, 747]
    Discuss this question
  2. 762. The mechanical system in which fresh air is blown into the room by centrifugal fans so as to create positive pressure and displace the vitiated air is termed as:

    • A. Balanced ventilation
    • B. Air conditioning
    • C. Exhaust ventilation
    • D. Plenum ventilation
    Show answer & explanation

    Answer: D. Plenum ventilation

    Correct Answer :- D. Plenum ventilation

    [Ref. Park 23/e p739]
    Discuss this question
  3. 763. The mean radiant temperature is measured by:

    • A. Dry bulb thermometer
    • B. Wet bulb thermometer
    • C. Six’s maximum and minimum thermometer
    • D. Globe thermometer
    Show answer & explanation

    Answer: D. Globe thermometer

    Correct Answer :- D. Globe thermometer

    [Ref. Park 23/e p732]

    • Instruments used in Air temperature:

    Instrument
    Dry bulb thermometer
    Wet bulb thermometer
    Maximum thermometer
    Minimum thermometer
    Six’s maximum and minimum thermometer
    Silvered thermometer
    Globe thermometer
    Wet Globe thermometer
    Kata thermometer

    Measures
    Air temperature
    Air temperature
    Air temperature
    Air temperature
    Air temperature
    Air temperature
    Mean radiant temperature
    Environmental heat
    Cooling power of Air; Low air velocities
    Discuss this question
  4. 764. Global warming true is:

    • A. CO<sub>2</sub> is a major greenhouse gas
    • B. Stratosphere ozone layer is harmful
    • C. CFC increases stratosphere ozone layer
    • D. Kyoto protocol called for 20% reduction in green- house emissions
    Show answer & explanation

    Answer: A. CO<sub>2</sub> is a major greenhouse gas

    Correct Answer :- A. CO2
    is a major greenhouse gas

    [Ref. Wikipedia]

    GREENHOUSE GASES
    • Water vapour (Highest contribution)
    • Carbondioxide (Second highest contribution)
    • Methane
    • Ozone
    – Ozone layer: Is beneficial as it cuts down UV transmission
    • CFCs depletes ozone layer
    Discuss this question
  5. 765. Which of the following is not a source of Indoor Air Pollution?

    • A. Carbon monoxide
    • B. Nitrogen dioxide
    • C. Radon
    • D. Mercury vapour
    Show answer & explanation

    Answer: D. Mercury vapour

    Correct Answer :- D. Mercury vapour

    [Ref. K. Park 23/e p735-736]

    Sources of Indoor Air Pollution: (Mnemonic: C MORON SCARF)

    Indoor air pollutant
    Respirable particles
    Carbon monoxide
    Nitrogen dioxide
    Sulphur dioxide
    Carbon dioxide
    Formaldehyde
    Organic vapours (benzene, toulidine)
    Ozone
    Radon & daughters
    Asbestos
    Mineral fibres

    Sources
    Tobacco smoke, Stove, Aerosols
    Combustion equipment, Stove, Gas heaters
    Gas cookers, Cigarettes
    Coal combustion
    Combustion, Respiration
    Particle board, Carpet adhesives, Insulation
    Solvents, Adhesives, Resins, Aerosols
    Electric arcing, UV light
    Building materials
    Insulation, Fire-proofing
    Appliances
    Discuss this question
  6. 766. Indoor air pollution does not cause:

    • A. Chronic lung disease
    • B. Pregnancy problems
    • C. Childhood pneumonia
    • D. Neuro-developmental problems
    Show answer & explanation

    Answer: D. Neuro-developmental problems

    Correct Answer :- D. Neuro-developmental problems

    [Ref. K Park 23/e p735-736]

    Effects of indoor air pollution
    • Acute respiratory tract infections (Pneumonias)
    • Chronic lung disease
    • Lung cancers in adults
    • Adverse pregnancy outcomes (Especially stillbirths)
    Discuss this question
  7. 767. Which of the following is non-natural gas causing green house effect?

    • A. Carbon dioxide
    • B. Methane
    • C. Ozone
    • D. CFCs
    Show answer & explanation

    Answer: D. CFCs

    Correct Answer :- D. CFCs

    [Ref. Global Change of Planet Earth OECD, p48]
    Discuss this question
  8. 768. Acceptable level for physical comfort:

    • A. Corrected effective temperature 77-80ºF
    • B. Corrected effective temperature 70-76ºF
    • C. Corrected effective temperature 80-81ºF
    • D. Corrected effective temperature >82ºF
    Show answer & explanation

    Answer: A. Corrected effective temperature 77-80ºF

    Correct Answer :- A. Corrected effective temperature 77-80ºF

    [Ref. K Park 23/e p732]
    Discuss this question
  9. 769. Which agency monitors air quality in India?

    • A. Central Research Institute
    • B. Ministry if health and Family Welfare
    • C. National Environmental Engineering Research Institute
    • D. Central Pollution Control Board
    Show answer & explanation

    Answer: D. Central Pollution Control Board

    Correct Answer :- D. Central Pollution Control Board

    [Ref. K Park 23/e p737]
    Discuss this question
  10. 770. In winter, water vapours and pollutants comes to lie in the lowermost layer of atmosphere by:

    • A. Acid rain
    • B. Green house effect
    • C. Temperature inversion
    • D. Ocean effect
    Show answer & explanation

    Answer: C. Temperature inversion

    Correct Answer :- C. Temperature inversion

    [Ref. Encyclopedia of Climate and Weather by Schneider, Root & Mastrandrea, 2/e (Volume 3) p392]
    Discuss this question
  11. 771. At which level of heat stress index it is not possible to work comfortably causing threat to health:

    • A. 20 - 40
    • B. 40 - 60
    • C. 60 - 80
    • D. 80 – 100
    Show answer & explanation

    Answer: B. 40 - 60

    Correct Answer :- B. 40 – 60

    [Ref. Park 23/e p747]

    Heat Stress Index (HSI)
    HSI %
    0
    10-30
    40-60
    70-90
    100
    >100

    Consequence of 8 hour exposure
    No thermal strain
    Mild-Moderate heat stress, Minimal impairment in work
    Severe heat stress, Threat to health if not fit
    Very severe heat stress, only few can sustain it
    Maximum heat stress, only young fit acclimatized can sustain it
    Varying degress of stress due to hyperthermia
    Discuss this question
  12. 772. Which of the following is not a feature of heat stress?

    • A. Hyperpyrexia
    • B. Syncope
    • C. Cramps
    • D. Numbness
    Show answer & explanation

    Answer: D. Numbness

    Correct Answer :- D. Numbness

    [Ref. Park 23/e p747-748]

    EFFECTS OF HEAT STRESS
    • Heat stroke: Body temperature >110ºF, Delirium, Convulsions, Absence of sweating
    • Heat hyperpyrexia
    • Heat exhaustion
    • Heat cramps
    • Heat syncope
    Discuss this question
  13. 773. Number of air changes in a drawing room per hour should be at least:

    • A. 2-3
    • B. 3-4
    • C. 4-5
    • D. 5-6
    Show answer & explanation

    Answer: A. 2-3

    Correct Answer :- A. 2 – 3

    [Ref. Park 21/e p681, Park 22/e p685]
    Discuss this question
  14. 774. Number of air changes in one hour in a work room should be at least:

    • A. 2-3
    • B. 3-4
    • C. 4-6
    • D. 5-7
    Show answer & explanation

    Answer: C. 4-6

    Correct Answer :- C. 4 – 6

    [Ref. Park 21/e p681, Park 22/e p685]
    Discuss this question
  15. 775. Acceptable level for physical comfort:

    • A. Corrected effective temperature 79°F
    • B. Corrected effective temperature 70-76°F
    • C. Corrected effective temperature 80-81°F
    • D. Corrected effective temperature > 82°F
    Show answer & explanation

    Answer: A. Corrected effective temperature 79°F

    Correct Answer :- A.Corrected effective temperature 79°F

    [Ref. Park 23/e p732]
    Discuss this question
  16. 776. In Indoor air pollution, carbon monoxide is produced by:

    • A. Combustion equipment
    • B. Stove
    • C. Gas heaters
    • D. All of the above
    Show answer & explanation

    Answer: D. All of the above

    Correct Answer :- D. All of the above

    [Ref. Park 23/e p735-736]
    Discuss this question
  17. 777. Relative humidity is determined by:

    • A. Kata thermometer
    • B. Anemometer
    • C. Sling psychrometer
    • D. Gardbad apparatus
    Show answer & explanation

    Answer: C. Sling psychrometer

    Correct Answer :- C. Sling psychrometer

    [Ref. Park 23/e p749]
    Discuss this question
  18. 778. Whispering produces a sound of:

    • A. 20-30 dB
    • B. 30-40 dB
    • C. 40-50 dB
    • D. 50-60 dB
    Show answer & explanation

    Answer: A. 20-30 dB

    Correct Answer :- A. 20-30 dB

    [Ref. K. Park 23/e p742]

    • Human ear is sensitive to sound frequency: 20 – 20,000 Hz
    • Daily maximum tolerable sound level to human ear (without substantial damage to their hearing): 85 – 90 dB
    – Auditory fatigue appears in: 90 dB region (greatest at 4000 Hz)
    • Sound level above which tympanic membrane rupture (permanent mechanical damage): 150 – 160 dB
    • Sound levels of some noises:
    – Whisper: 20 – 30 dB
    – Normal conversation: 60 – 70 dB
    – Mechanical damage: 150 – 160 dB (e.g Jet taking off)
    • Acceptable noise levels: expressed in dB (A), sound pressure levels conforming to weighting curve (A)

    Environment
    Residential
    Commercial
    Industrial
    Educational
    Hospitals

    Place
    Bed room
    Living room
    Office
    Conference
    Restaurants
    Workshop
    Laboratory
    Class room
    Library
    Wards

    Acceptable noise level dB (A)
    25
    40
    35 – 45
    40 – 45
    40 – 60
    40 – 60
    40 – 50
    30 – 40
    35 – 40
    20 – 35

    Also Remember
    • 20th century has been described as ‘Century of noise’
    • Basic instruments used in studies of noise:

    Instrument
    Sound Level Meter
    Octave Band Frequency Analyser
    Audiometer

    Use
    Measures intensity of sound in dB or dB(A)
    Shows ‘sound spectrum’, characteristic (pitch)
    Measures hearing ability

    • Most Temporary Hearing loss occurs in the frequency range: 4000-6000 Hz.





    Discuss this question
  19. 779. Recommended illumination range for regular work is _______ foot-candles:

    • A. 6-12
    • B. 25-50
    • C. 50-75
    • D. 75-100
    Show answer & explanation

    Answer: A. 6-12

    Correct Answer :- A. 6-12

    [Ref. Park 23/e p739]

    • Basic minimum illumination for satisfactory vision: 15 – 20 foot candles
    Discuss this question
  20. 780. The optimum floor space recommended per adult person in a dwelling place is:

    • A. 50–100 sq.ft.
    • B. 101–450 sq.ft.
    • C. 151–200 sq.ft.
    • D. 201–250 sq.ft.
    Show answer & explanation

    Answer: A. 50–100 sq.ft.

    Correct Answer :- A. 50—100 sq.ft.

    [Ref. Park 23/e p752]

    • Recommend per capita space in urban houses: 50-100 sq-ft.
    # Also Remember
    • Accepted standards of overcrowding:
    – Persons per room:

    No. of rooms
    1 rooms
    2 rooms
    3 rooms
    4 rooms
    5 rooms
    (additional 2 for each further room)

    Maximum no. of persons
    2 persons
    3 persons
    5 persons
    7 persons
    10 persons

    Floor space per person: Child between 1 – 10 years is counted as ½ unit; infant is not counted

    Floor space
    > 110 sq. ft.
    90 – 110 sq. ft.
    70 – 90 sq. ft.
    50 – 70 sq. ft.
    < 50 sq. ft.

    Maximum no. of persons
    2 persons
    1½ persons
    1 person
    ½ person
    Nil

    – Sex separation: Overcrowding is said to exist if two persons over 9 years of age, not husband and wife, of opposite sexes are obliged to sleep in the same room
    • Recommended spaces:
    – Floor space per person in a house: minimum 90 – 110 sq. ft.
    – Floor area per student in a class: > 10 sq. ft.
    – Space per worker in a factory (The Factory Act, 1948): >500 cu. ft.


    Discuss this question