Anatomy MCQs for Medical NMCLE / Loksewa / MDMS Exams – Page 118
2,839 Anatomy multiple-choice questions with answers and explanations, from the ExamsNepal question bank for Medical NMCLE / Loksewa / MDMS Exams. Try each question first, then open the answer to check your reasoning.
In ExamsNepal mock tests, students answer 54% of Anatomy questions correctly (3,227 answers).
Preparing for MECEE-PG - MD/MS Entrance, NMC Licensing Examination (NMCLE) or NMC Special Examination? See the exam pattern, syllabus and free mock tests.
2341. Stresses of resin - dentin interface is due to
- A. Configuration factor
- B. Coefficient of thermal expansion
- C. Occlusal loading
- D. All of above
Discuss this questionShow answer & explanation
Answer: D. All of above
Configuration factor: ratio of bonded to unbonded surface. In occlusal preparation, composite bonded to five surface (mesial, distal, buccal, lingual and pulpal) whereas unbonded to occlusal surface. Hence, C Factor is 5: 1
4,- Increase C Factor, increase the polymerization shrinkage During curing bonded surface are in state of stress whereas unbonded surface are in state of relaxed. Unrelieved stresses in composite contribute to internal bond disruption and marginal gap around restoration that causes micro leakage are potential post-operative sensitivity.
Coefficient of thermal expansion of composite is about four times greater than of tooth structure.2342. Key ingredient in primers of dentin bonding agent is
- A. META
- B. Bis- GMA
- C. HEMA
- D. PENTA
Discuss this questionShow answer & explanation
Answer: C. HEMA
META is most frequently used amalgam bonding agent. Since, META a potential coupling agent used as multipurpose bonding agent (enamel bonding agent, dentin bonding agent, amalgam bonding agent, composite to metal for fracture repair)
- META and HEM.4 has both hydrophilic and hydrophobic components.
META, so called as universal bonding agent.2343. Bonding strength of dentin bonding agent is
- A. 16-35mpa
- B. 2- 6 mpa
- C. 18- 22 mpa
- D. 20-23 mpa
Discuss this questionShow answer & explanation
Answer: A. 16-35mpa
Bonding strength of dentin bonding agent ranges from 16- 35 mpa, reduces with increased depth of dentin Bonding strength Mpa
Acid etched enamel + composite 18 - 20
Dentin + META 18- 20
Enamel + META 2- 3
Amalgam + META 2- 5
Acid etched enamel + HEMA 23- 25
Acid etched dentin + HEMA 16- 35
-The minimum bond strength for proper adhesion should be 20 Mpa for restoration whereas 5 Mpa for orthodontic adhesives that allows penetration of silver nitrate dye.2344. Small porosities in hybrid layer is called
- A. Micro leakage
- B. Nano leakage
- C. Marco leakage
- D. All of above
Discuss this questionShow answer & explanation
Answer: B. Nano leakage
Nano leakage- small porosities in hybrid layer or at the transition between hybrid layer or mineralized dentin that allow penetration of minuscule particle of silver nitrate dye.
Micro leakage- passage of bacteria or their toxin between restoration margin and tooth preparation wall.
Becomes important when one considers pulpal irritation.2345. Role of water in bonding process is
- A. Act as scavenger
- B. Cross linking agent
- C. As a plasticizer
- D. Not required
Discuss this questionShow answer & explanation
Answer: C. As a plasticizer
Critical amount of water acts as plasticizer for bonding agent prevent collapse of collagen network but over wet condition decrease bond strength and formation of blister structure at interface.2346. Which of the following generation introduced total etch technique ?
- A. 3rd generation
- B. 4th generation
- C. 5th generation
- D. 6th generation
Discuss this questionShow answer & explanation
Answer: B. 4th generation
Total etch technique - also called as etch and rinse technique
- Etch both enamel and dentin and help to remove the entire smear layer.
- Self etch technique - no rinsing required, hybrid layer resin- impermeable smear plug is formed.
-First introduced in 6th generation of dentin bonding agent.2347. The polar interaction between negatively charged phosphate group in resin and positively charged calcium ion in smear layer based on which generation of bonding agent ?
- A. 1st generation
- B. 2nd generation
- C. 4th generation
- D. 5th generation
Discuss this questionShow answer & explanation
Answer: B. 2nd generation
1st generation bonding agent- supposed to chelate with calcium in dentin to form water resistant chemical bond to dentin.
3rd generation bonding agent - removal of smear layer without disturbing smear plugs that occlude dentinal tubules.
4th and 5th generation- based on etch and rinse adhesives concept
6th and 7th generation- based on self etch adhesives concept.
2348. ln dentistry bonding of resin based material to tooth structure is result of
- A. Mechanical adhesion
- B. Adsorption adhesion
- C. Diffusion adhesion
- D. All of above
Discuss this questionShow answer & explanation
Answer: D. All of above
Bis- GMA - Bisphenol - glycidyl methacrylate
EDTA - Ethylenediamine tetracetic acid
HEMA -2 - hydoxymethyl methacrylate
cr 4- META - 4- Methacryloxyethyl trimelliate anhydride NPG- GMA- N - phenyl glycine- glycidyl methacrylate TEGMA - Triethylene glycol dimethacrylate
ce UDMA- Urethene dimethactylate
@Bonding agent should be contraindicated after bleaching a tooth.
@Bonding agent in composite resin is micromechanical bonding
@Adsorption adhesion - chemical bonding (involved forces may be primary valence forces - ionic and covalent or secondary valence forces - hydrogen or Vander wall bond) @Diffusion adhesion - interlocking between molecule through diffusion of polymer chain ends across an interface.
2349. Bowen`s resin called as
- A. Bis GMA
- B. HEMA
- C. TEGDMA
- D. UDMA
Discuss this questionShow answer & explanation
Answer: A. Bis GMA
Note:
`Bowen`s resin consists of 3 parts of bisGMA and one part of
methymethacrylate(MMA)2350. Commonly used diluent in composite is
- A. Bis GMA
- B. UDMA
- C. HEMA
- D. TEGDMA
Discuss this questionShow answer & explanation
Answer: D. TEGDMA
Addition of TEGDMA (triethylene glycal dimethacrylate)
reduce the viscocity of bisGMA2351. Which of the following is correct about filler used in composite?
- A. Increased Hardness strength and decreased wear
- B. Decreased in polymerization shrinkage
- C. Decreased Coefficient of thermal expansion and water
- D. All of above
Discuss this questionShow answer & explanation
Answer: D. All of above
Fillers also increase workability by increasing the viscocity of composite and also increased radiopacity2352. Essential component of composite includes except
- A. Resin matrix
- B. Activator
- C. Filler
- D. Coupling agent
Discuss this questionShow answer & explanation
Answer: B. Activator
Note: Compasition of composite
Essential component:
Resin matrix or binder: forms continuous phase and
made up of bisGMA and UDMA
Highly crosshnked structure and highly viscous
Addition of TEGDMA to reduce the viscocity of bisGMA -
acts as diluent
Strong air inhibition to polymerization and high water
sorption because of diluent used.
Filler: colloidal sihca (most commonly used), quartz,
heavy metal glass, sihcates, fluoride releasing filler
(ytterbium trifluoride, Ba- Al- fluorosilicate glass)
Coupling agents: organosilanes ie gamma- methacryloxy
propyltrimethoxysilane
Bonds the filler to the resin matrix so occlusal load are
transferred from matrix to filler particle
Inhibit leaking by preventing water from penetration into
matrix filler interfere or reduce the wear
Forms siloxane bond to filler ar covalent bond with resin
matrix
Zirconates and titanates also be used as coupling agent
= Additional components:
1 Chemically activated composite
Initiator - base paste which contain benzoyl
peroxide
Activator or catalyst paste which contain N, N
dimethyl-p-toluidine, a tertiary amine,
2 Light (visible) activated composite
Photainitiater: camphoroquinone (0.2%)
Amine accelerator - dimethylaminoethy
methacrvlate(0. 15%)
Activator- visible light (400-500 nm)
Inhibitor - butylated hydroxyl toluene (0.01%) 1, Prevent
premature polymerization. The reactivity of BHT is
greater with free radicals (released during the Induration
stage of polymerization) than the monomer. Because of
this chain propagation stage is prevented.
Opacifier - titanium dioxide or aluminium oxide to attain
natural shade of tooth structure
© UVabsorbers - to improve color stability2353. The various method to increase microfiller leading are:
- A. Addition of agglomerated silica
- B. Addition of prepolymerized fillers
- C. Addition of organic fillers
- D. All of above
Discuss this questionShow answer & explanation
Answer: D. All of above
© Agglomerated siljcq. sintered (fused) colloidal silica
particles thereby reducing surface area
Prepolymerized fillers. 60-70% wt of silane coated colloidal silica. Also called as an organic filler, common method used to increase microfiller loading2354. The particle size ranges from 10-100um in
- A. Macrofiller
- B. Microfiller
- C. Hybrid
- D. Nanofiller
Discuss this questionShow answer & explanation
Answer: A. Macrofiller
Macrofiter 10 - 100 um
Midifiller. 1 10 um
Misnfiler- 0.1- um
Mic rofifler 114) - 0.1 um
Hybrid ranges of ie ine lu,2355. Which of the following has greatest filler loading?
- A. Conventional
- B. Small particle filled
- C. Microfilled
- D. Hybrid
Discuss this questionShow answer & explanation
Answer: C. Microfilled
Microfilled composite is a choice material in restoring low occlusal wear,high esthetic area for restoring class V conical lesion.2356. Normally in adults, spinal cord ends at the level of
- A. T12
- B. L1
- C. L4
- D. S1
Discuss this questionShow answer & explanation
Answer: B. L1
. Spinal cord begins at the foramen magnum, and it terminates at the level of the lower border of L1(in adult), upper border of L3 (in children).
. Duramater extends upto sacrum and coccyx.
Structure /Space Terminal extent
Spinal cord at birth L3 vertebrae (upper border)
Spinal cord in 2 L1 (lower border) or L2 (upper border)
ear infant
Filum terminale Attached to first caccygeal segment
Filum terminal S2 vertebrae (lower border)
einternum
Filum terminale Attached to first coccygeal segment
externum
Piamater and dura- Attached to first coccygeal segment
mater
Subarachnoid sheath S2 vertebrae (lower border)
Subarachnoid space
Subdurals ace2357. The medial geniculate body is associated with:
- A. Taste
- B. Vision
- C. Hearing
- D. Olfaction
Discuss this questionShow answer & explanation
Answer: C. Hearing
. The primary and secondary auditory areas receive fibres from the medial geniculate body via the auditory radiation.
. The lateral geniculate body receives retinal fibres of both the eyes (from temporal half of the retina of the same side and nasal half of the retina of the opposite side) through optic tract and gives rise to fibres of the optic radiation which convey visual impulses to the visual cortex of the occipital lobe.
. Remember M for medial and music & L for Light and lateral
Ref: Clinical Neuroanatomy Snell 7th ed page 3722358. Maximum thickness of increments recommended for light cured at a time is:
- A. 1mm
- B. 3mm
- C. 2mm
- D. 0.5mm
Discuss this questionShow answer & explanation
Answer: C. 2mm
It is generally recommended that no more than 1.5-2m,
increment be light cured at a time2359. Hyoid bone develops from:
- A. 1st and 2nd arches
- B. 2nd and 3rd arches
- C. 3rd and 4th arch
- D. 1st , 2nd and 3rd arches
Discuss this questionShow answer & explanation
Answer: B. 2nd and 3rd arches
. It is U-shaped bone is located in the front of the neck between the mandible and the larynx at the level of the 3rd cervical vertebra. It is unique in the sense that, it does not articulate with any other bone in the body, but it is suspended from styloid processes of temporal bones by stylohyoid ligaments
Ref: Langman`s Embryology 12th ed page 2642360. Which of the following is correct except?
- A. Increased Intensity of light decrease the Curing time
- B. Smaller filler particle greater the curing depth
- C. Darker the shade of resin longer the curing time
- D. Increased Thickness of resin, increased the Curing time
Discuss this questionShow answer & explanation
Answer: B. Smaller filler particle greater the curing depth
Smaller the filler particle. more interfere with light and maximum scattering, hence microfilled composites with smaller and more numerous particles will not cure to gg
great a depth as conventional composites
@Light from visible light curing unit can cause retinal
damage